Auto-correlation Function Study of Scattered Light Intensity
نویسنده
چکیده
In this work, the particle size distribution measured using the dynamic light scattering (DLS) technique is compared with that obtained from the static light scattering (SLS) technique or provided by the supplier measured using the Transmission Electron Microscopy (TEM) technique for dilute Poly(N-isopropylacrylamide) microgel and standard polystyrene latex samples in dispersion respectively. The results show that the narrow particle size distribution that can be measured accurately using the SLS technique is not suited to the determination by the DLS technique and the particle size distribution obtained from the DLS technique is different from the value provided by the supplier. With the assistance of the simulated data of the normalized time auto-correlation function of the scattered light intensity g (τ), the effects of the particle size distribution on the nonexponentiality of g (τ) measured at a scattering angle of 30 are investigated. The analysis reveals that the influences of the particle size distribution are small on the nonexponentiality of g (τ ) and very large on the initial slope of the logarithm of g (τ ). The values of the apparent hydrodynamic radius are also largely influenced by the particle size distribution and the difference between the distributions of the apparent hydrodynamic radius and hydrodynamic radius of particles is determined by the method of cumulants.
منابع مشابه
Auto-correlation Function Analysis of Scattered Light Intensity at Different Scattering Angles
In this work, the effects of the scattering angle on the nonexponentiality of the normalized time auto-correlation function of the scattered light intensity g (τ ) are investigated using dilute Poly(N-isopropylacrylamide) microgel and standard polystyrene latex samples in dispersion respectively. The results show that the influences of the scattering angle on the deviation between an exponentia...
متن کاملInvestigating Auto-correlation of Scattered Light of Mixed Particles
In this work, the normalized time auto-correlation function of the electric field of the light g (τ ) that is scattered by the two kinds of particles in dispersion is investigated. The results show that the logarithm of g (τ) can be consistent with a line and many reasons can cause the deviations between an exponentiality and plots of g (τ ) as a function of delay time τ . The nonexponentiality...
متن کاملChange of diffused and scattered light with surface roughness of p-type porous Silicon
Porous silicon samples were prepared by electrochemical etching method for different etching times. The structural properties of porous silicon (PS) samples were determined from the Atomic Force Microscopy (AFM) measurements. The surface mean root square roughness (σ rms) changes as function of porosity were studied, and the influence of etching time on porosity and roughness was studied too. U...
متن کاملChange of diffused and scattered light with surface roughness of p-type porous Silicon
Porous silicon samples were prepared by electrochemical etching method for different etching times. The structural properties of porous silicon (PS) samples were determined from the Atomic Force Microscopy (AFM) measurements. The surface mean root square roughness (σ rms) changes as function of porosity were studied, and the influence of etching time on porosity and roughness was studied too. U...
متن کاملAdvances in dynamic light scattering techniques
Recent developments in processing techniques and detection hardware have opened new horizons for the application of light scattering methods based on the dynamic analysis of coherent scattered light. Increased computational power of modern microprocessors allow real-time data evaluation on standard desktop computers. The continuous improvement of detector arrays, such as cameras based on CCD or...