Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The objective was to evaluate the results of high-resolution, fast-speed, section-interpolation MR angiography and digital subtraction angiography (DSA), thereby examining the potential use of a primary noninvasive screening test for intracranial aneurysms. METHODS The images were obtained in 39 cerebral aneurysmal lesions from 30 patients with a time-of-flight MR angiographic technique using a 1.5-T superconducting MR system. The total image volume was divided into four slabs, with 48 partitions each. To save time, only 24 phase-encoded steps were measured and interpolated to 48. The parameters used included 30/6.4 (TR/TE), a flip angle of 25 degrees , a 160x512 matrix, a field of view of 150x200, 7 minutes 42 seconds of scan time, an effective thickness of 0.7 mm, and an entire thickness of 102.2 mm. Maximum intensity projection was used for the image analysis, and a multiplanar reconstruction technique was used for patients with intracranial aneurysms. RESULTS Among 39 intracranial aneurysmal lesions in 30 patients, 21 were ruptured and 18 were unruptured. Twelve lesions were less than 2 mm in size, 12 were 3 to 5 mm, 12 were 6 to 9 mm, and three were larger than 10 mm. At initial examinations, 38 of 39 aneurysmal lesions were detected by both MR angiography and DSA, with 97% sensitivity. In confirming aneurysms in neck and parent vessels, multiplanar reconstruction was successful in detecting all 39 aneurysms, whereas MR angiography was successful in detecting 27 (69%) and DSA was successful in detecting 32 (82%) of the lesions. CONCLUSION High-resolution MR angiography with a section-interpolation technique showed equal results to those of DSA for the detection of intracranial aneurysms and may be used as a primary noninvasive screening test. In the evaluation of aneurysms in neck and parent vessels, the concurrent use of MR angiography and multiplanar reconstruction was far superior to the use of either MR angiography or DSA alone.
منابع مشابه
Large-cohort comparison between three-dimensional time-of-flight magnetic resonance and rotational digital subtraction angiographies in intracranial aneurysm detection.
BACKGROUND AND PURPOSE The value of MR angiography varies in diagnosis of intracranial aneurysms due to the difference of equipment and imaging technique. This study was to compare the effectiveness of 3-dimensional time-of-flight MR angiography at 3 T and rotational digital subtraction angiography, both with volume rendering (VR), in detecting intracranial aneurysms. METHODS One hundred thir...
متن کاملThree-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.
BACKGROUND AND PURPOSE Our aim was to develop 3D dynamic MR digital subtraction angiography with high temporal resolution without sacrificing spatial resolution by using sensitivity encoding for the evaluation of cerebral arteriovenous malformations. METHODS Nineteen patients with 19 angiographically proven arteriovenous malformations (16 supratentorial and 3 infratentorial) were assessed by ...
متن کاملMulti-section CT angiography for detection of cerebral aneurysms.
BACKGROUND AND PURPOSE Multi-section CT has great potential for use in vascular studies. Our purpose was to determine the accuracy of multi-section CT angiography in detecting cerebral aneurysms compared with digital subtraction angiography or surgery. METHODS One hundred consecutive patients who underwent multi-section CT angiography and either digital subtraction angiography or surgery were...
متن کاملMR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.
We evaluated a time-of-flight three-dimensional MR angiographic sequence with an ultrashort echo time for its ability to characterize the perfusional state of cerebral aneurysms that had been treated with Guglielmi detachable coils and to depict adjacent cerebral arteries. The results were compared with findings at conventional MR angiography and digital subtraction angiography. Adjacent vessel...
متن کاملThree-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils.
BACKGROUND AND PURPOSE Intravascular treatment of intracranial aneurysms is a relatively new therapeutic technique and long-term controlled angiographic trials are needed to assess persistence of aneurysm occlusion. Our purpose was to evaluate the effectiveness of 3D time-of-flight (3D-TOF) MR angiography as a noninvasive screening tool in the follow-up of cerebral aneurysms treated with Guglie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 20 2 شماره
صفحات -
تاریخ انتشار 1999