Experimental Assessment of Imbalance Conditions in a Tripolar Cuff for ENG Recordings
نویسندگان
چکیده
Functional Electrical Stimulation (FES) may be improved by the use of naturally occurring nerve signals as feedback signals. However, the usefulness of the recorded electroneurogram (ENG) signals from nerve cuff electrodes depends on the amount of electromyogram (EMG) interference and stimulus artefact present. Tripolar cuff electrodes reduce interference but suffer from imbalance, which degrades the performance of amplifier recording configurations. Previously cuff imbalance has been mainly associated with impedance variations inside the cuff and cuff asymmetry. In this paper, imbalance is associated with additional factors, including cuff orientation and distance from the interference source. The findings are based on in-vivo and in-vitro experiments performed using a true-tripole amplifier recording system.
منابع مشابه
Bioelectric field simulations for studying cuff-electrode interface errors
Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar nerve cuff electrodes, in combination with appropriate amplifier schemes. In practice the cuff departs from its ideal model leading to cuff imbalance. As a result, the output nerve signal of such amplifiers has been widely reported to be degraded by interference,...
متن کاملAn Interface for Nerve Recording and Stimulation with Cuff Electrodes
A nerve cuff electrode interface capable of both stimulating and recording from a nerve is described. The interface also rejects the EMG contamination in the recordings using reactive components without adding noise to the ENG signal. A transformer is added to the design for noise matching and the signal-to-noise ratio improvement is evaluated for a specific amplifier INTRODUCTION Electroneurog...
متن کاملModeling study of peripheral nerve recording selectivity.
Recording of sensory information from afferent fibers can be used as feedback for the closed-loop control of neural prostheses. Clinical applications suggest that recording selectively from various nerve fascicles is important. Current nerve cuff electrodes are generally circular in shape and use a tripolar recording configuration. Preliminary experiments suggest that slowly changing the shape ...
متن کاملConsiderations on Improving the Design of Cuff Electrode for ENG Recording - Geometrical Approach, Dedicated IC, Sensitivity and Noise Rejection
Cuff electrodes have several advantages for in situ recording ENG signal. They are easy to implant and not very invasive for the patient. Nevertheless, they are subject to background parasitic noise, especially the EMG generated by the muscles. We show that the use of cuff electrodes with large numbers of poles can to increase their sensitivity and their selectivity with respect to a efficient ...
متن کاملConsiderations on Improving the Design of CUFF Electrode for ENG Recording - Geometrical Approach, Dedicated IC, Sensitivity, Noise Rejection
Cuff electrodes have several advantages for in situ recording ENG signal. They are easy to implant and not very invasive for the patient. Nevertheless, they are subject to background parasitic noise, especially the EMG generated by the muscles. We show that the use of cuff electrodes with large numbers of poles can to increase their sensitivity and their selectivity with respect to a efficient ...
متن کامل