Misleading statistical calculations in far-advanced glaucomatous visual field loss.
نویسندگان
چکیده
OBJECTIVE In this study, the capability of statistical analysis indices to characterize static automated visual fields (VFs) accurately in cases of far-advanced glaucoma was assessed. DESIGN Retrospective observational case series. PARTICIPANTS Sixteen eyes of 15 patients with end-stage glaucoma and evidence of collapse of VF statistical analysis indices were included in the study. METHODS End-stage glaucoma was defined as vertical cup-to-disc ratio of 0.9 or more, mean deviation less than -24 dB and with only a central or temporal island remaining in the VF gray scale. Collapse of statistical indices was defined as any of the following: pattern deviation probability plot without a single VF location showing P < 0.5%; corrected pattern standard deviation (CPSD) and pattern standard deviation (PSD) probability less than 5% or within normal limits (WNL); short-term fluctuation (SF) probability WNL; glaucoma hemifield test (GHT) not outside normal limits (ONL); or presence of a low patient reliability comment triggered by 40% or more false-negative (FN) responses. MAIN OUTCOME MEASURES Visual field statistical indices. RESULTS Of the 16 VFs showing misleading statistical calculations, 9 of 16 eyes had a normal pattern deviation probability plot. The PSD, SF, and CPSD parameters were normal or barely outside the normal range in 4 of 16, 10 of 16, and 5 of 16 eyes, respectively. The GHT was ONL in 7 of 13 eyes, borderline with generalized reduction of sensitivity (GRS) in three eyes, and only GRS in two additional eyes. Low patient reliability was triggered because of an FN score of 40% or more in 10 of 16 eyes. CONCLUSIONS Statistical indices are crucial for the interpretation of automated static VFs. However, in end-stage glaucomatous VF loss, both summary statistical indices and reliability indices may not detect abnormality, thus misleading the casual observer.
منابع مشابه
Frequency doubling technology perimetry for detection of glaucomatous visual field loss.
PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کامل[Relationship between central corneal thickness, intraocular pressure and severity of glaucomatous visual field loss].
OBJECTIVE to determine central corneal thickness in normal subjects, glaucomatous patients and ocular hypertension patients, to evaluate if the central corneal thickness is related to the presence of glaucoma or ocular hypertension. Furthermore, we aim to verify the relationship between central corneal thickness and severity of glaucomatous visual field loss. METHODS comparative study includi...
متن کاملThe structure-function relationship in eyes with glaucomatous visual field loss that crosses the horizontal meridian.
OBJECTIVE To evaluate the relationship between visual field loss and glaucomatous optic discs in eyes in which field loss spreads across the horizontal meridian. SUBJECTS AND METHODS Ninety-six patients with glaucoma (9 advanced, 60 moderate, and 27 early) with 2 successive abnormal fields were included. Standard achromatic automated perimetry defects were identified with a nerve fiber bundle...
متن کاملDiagnostic accuracy of the Moorfields Regression Analysis using the Heidelberg Retina Tomograph in glaucoma patients with visual field defects.
PURPOSE This study was designed to determine the specificity and sensitivity of the Heidelberg Retina Tomograph I (HRT) using the Moorfields Regression Analysis (MRA) in differentiating healthy from glaucomatous eyes. METHODS In this cross-sectional study, 74 eyes of 37 healthy subjects and 87 eyes of 47 glaucoma patients were examined with Octopus standard automated perimetry and HRT. Only o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 110 1 شماره
صفحات -
تاریخ انتشار 2003