Defining the impaction frequency and threshold force required for femoral impaction grafting in revision hip arthroplasty
نویسندگان
چکیده
BACKGROUND AND PURPOSE The two most common complications of femoral impaction bone grafting are femoral fracture and massive implant subsidence. We investigated fracture forces and implant subsidence rates in embalmed human femurs undergoing impaction grafting. The study consisted of two arms, the first examining the force at which femoral fracture occurs in the embalmed human femur, and the second examining whether significant graft implant/subsidence occurs following impaction at a set force at two different impaction frequencies. METHODS Using a standardized impaction grafting technique with modifications, an initial group of 17 femurs underwent complete destructive impaction testing, allowing sequentially increased, controlled impaction forces to be applied until femoral fracture occurred. A second group of 8 femurs underwent impaction bone grafting at constant force, at an impaction frequency of 1 Hz or 10 Hz. An Exeter stem was cemented into the neomedullary canals. These constructs underwent subsidence testing simulating the first 2 months of postoperative weight bearing. RESULTS No femurs fractured below an impaction force of 0.5 kN. 15/17 of the femurs fractured at or above 1.6 kN of applied force. In the second group of 8 femurs, all of which underwent femoral impaction grafting at 1.6 kN, there was no correlation between implant subsidence and frequency of impaction. Average subsidence was 3.2 (1-9) mm. INTERPRETATION It is possible to calculate a force below which no fracture occurs in the embalmed human femur undergoing impaction grafting. Higher impaction frequency at constant force did not reduce rates of implant subsidence in this experiment.
منابع مشابه
The threshold force required for femoral impaction grafting in revision hip surgery
BACKGROUND AND PURPOSE Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow f...
متن کاملImpaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute
BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...
متن کاملCancellous impaction grafting in femoral revision THA.
Options in the management of the deficient femur during revision hip arthroplasty include cemented or cementless fixation. The results with cemented femoral revision have not been historically successful. While the use of extensively coated implants in revision total hip arthroplasty has been more uniformly excellent, issues, such as thigh pain, stress shielding, and lack of bone stock restorat...
متن کاملImpaction Grafting for Revision Total Hip Arthroplasty
Impaction grafting for revision total hip arthroplasty is increasingly being used in cases complicated by substantial bone loss. Many techniques using cemented and noncemented designs with or without bone graft have had unpredictable outcomes and are the source of continuing debate. This new technique uses morselized allograft, impacted into a constrained femoral envelope, creating a new medull...
متن کاملImpaction grafting of the femur in two-stage revision for infected total hip replacement.
We report the mid-term results of femoral impaction grafting which was used in 53 patients during the second stage of a two-stage revision for an infected total hip replacement. We reviewed all cases performed between 1989 and 1998. All patients underwent a Girdlestone excision arthroplasty, received local and systemic antibiotics and subsequently underwent reconstruction, using femoral impacti...
متن کامل