Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis

نویسندگان

  • Yun-Lin Chen
  • Tiao Lin
  • An Liu
  • Ming-Min Shi
  • Bin Hu
  • Zhong-li Shi
  • Shi-Gui Yan
چکیده

There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible years to present, with the search strategy of "(HA OR hydroxyapatite) AND ((total hip arthroplasty) OR (total hip replacement)) AND (RCT* OR randomiz* OR control* OR compar* OR trial*)". The randomized controlled trials and comparative observation trials that evaluated the clinical and radiographic effects between hydroxyapatite coating and porous coating were included. Our main outcome measurements were Harris hip score (HHS) and survival, while the secondary outcome measurements were osteolysis, radiolucent lines, and polyethylene wear. Twelve RCTs and 9 comparative observation trials were included. Hydroxyapatite coating could improve the HHS (p < 0.01), reduce the incidence of thigh pain (p = 0.01), and reduce the incidence of femoral osteolysis (p = 0.01), but hydroxyapatite coating had no advantages on survival (p = 0.32), polyethylene wear (p = 0.08), and radiolucent lines (p = 0.78). Hydroxyapatite coating has shown to have an advantage over porous coating. The HHS and survival was duration-dependent-if given the sufficient duration of follow-up, hydroxyapatite coating would be better than porous coating for the survival. The properties of hydroxyapatite and the implant design had influence on thigh pain incidence, femoral osteolysis, and polyethylene wear. Thickness of 50 to 80 μm and purity larger than 90% increased the thigh pain incidence. Anatomic design had less polyethylene wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta-analysis.

We conducted meta-analysis of clinical studies of HA coated femoral stems in hip arthroplasty. After an exhaustive literature search, we abstracted relevant data on the outcomes of stem survival from aseptic loosening and Harris Hip scores. The risk ratios and mean differences with 95% confidence intervals (CI) are reported. 9 studies met our inclusion criteria for the analysis. The cumulative ...

متن کامل

Hydroxyapatite Coating ~ to Porous-Coated Fixation

Fifteen patients had bilateral hip replacement with a porous-coated hip replacement in one hip and in the contralateral hip the same design. which had adjunctive hydroxyapatite coating on the porous coating. These patients were followed for an average of 6.5 years (range, 5-7.9 years). There was no difference in the clinical Harris Hip Scores between the two hips in these patients. The radiogra...

متن کامل

A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems

BACKGROUND AND PURPOSE Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was t...

متن کامل

A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem.

We investigated the implant-bone interface around one design of femoral stem, proximally coated with either a plasma-sprayed porous coating (plain porous) or a hydroxyapatite porous coating (porous HA), or which had been grit-blasted (Interlok). Of 165 patients implanted with a Bimetric hip hemiarthroplasty (Biomet, Bridgend, UK) specimens were retrieved from 58 at post-mortem. We estimated ing...

متن کامل

Hydroxyapatite augmentation of the porous coating improves fixation of tibial components. A randomised RSA study in 116 patients.

In a single-blind, randomised series of knee replacements in 116 patients, we used radiostereometric analysis (RSA) to measure micromotion in three types of tibial implant fixation for two years after knee replacement. We compared hydroxyapatite-augmented porous coating, porous coating, and cemented fixation of the same design of tibial component. At one to two years, porous-coated implants mig...