First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.
نویسندگان
چکیده
OBJECTIVES The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. METHODS The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. RESULTS The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. CONCLUSIONS Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures.
منابع مشابه
Fabrication, Packaging, and Catheter Assembly of 2d Cmut Arrays for Endoscopic Ultrasound and Cardiac Imaging
Ultrasound is increasingly in demand as a medical imaging tool and can be particularly beneficial in the field of intracardiac echocardiography (ICE). However, many challenges remain in the development of a 3D ultrasound imaging system. We have designed and fabricated a quad-ring capacitive micromachined ultrasound transducer (CMUT) for real-time, volumetric medical imaging. Each CMUT array is ...
متن کاملProgress in Development of HIFU CMUTs for use under MR-guidance
High intensity focused ultrasound (HIFU) guided by magnetic resonance imaging (MRI) is a noninvasive treatment that potentially reduces patient morbidity, lowers costs, and increases treatment accessibility. Traditionally, piezoelectric transducers are used for HIFU, but capacitive micromachined ultrasonic transducers (CMUTs) have many advantages, including fabrication flexibility, low loss, an...
متن کاملCapacitive Micromachined Ultrasonic Transducer Arrays for Integrated Diagnostic/Therapeutic Catheters
In recent years, medical procedures have become increasingly non-invasive. These include endoscopic procedures and intracardiac interventions (e.g., pulmonary vein isolation for treatment of atrial fibrillation and plaque ablation for treatment of arteriosclerosis). However, current tools suffer from poor visualization and difficult coordination of multiple therapeutic and imaging devices. Dual...
متن کاملDesign and Performance Analysis of Capacitive Micromachined Ultrasonic Transducer Linear Array
An ultrasonic transducer is a key component to achieve ultrasonic imaging. This paper designs a new type of Microelectromechanical Systems (MEMS) based capacitive ultrasonic transducer and a linear array based on the transducer. Through directivity analysis, it can be found that its directivity is weak due to the small size of the designed transducer, but the directivity of the designed linear ...
متن کاملA Miniature Real-Time Volumetric Ultrasound Imaging System
Progress made in the development of a miniature real-time volumetric ultrasound imaging system is presented. This system is targeted for use in a 5-mm endoscopic channel and will provide real-time, 30-mm deep, volumetric images. It is being developed as a clinically useful device, to demonstrate a means of integrating the front-end electronics with the transducer array, and to demonstrate the a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 31 2 شماره
صفحات -
تاریخ انتشار 2012