Tissue temperature monitoring with multiple gradient-echo imaging sequences.

نویسندگان

  • R V Mulkern
  • L P Panych
  • N J McDannold
  • F A Jolesz
  • K Hynynen
چکیده

The inherent sensitivity of multiple gradient-echo sequences to the chemical shift is exploited to rapidly map muscle water frequency shifts caused by ultrasonic heating. The use of multiple echoes is shown to offer several advantages over single gradient-echo approaches previously proposed for temperature measurement. An increase in the effective bandwidth significantly reduces aliasing problems observed with single gradient-echo methods in high temperature applications. Of greater significance is the improved immunity to intrascan motion found for multi-echo versus single echo gradient methods, making the former more attractive for clinical applications. Finally, a sensitivity to the presence of multiple spectral components unavailable with single gradient-echo methods is obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.

MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal ...

متن کامل

MR imaging-related heating of deep brain stimulation electrodes: in vitro study.

BACKGROUND AND PURPOSE Recent work has shown a potential for excessive heating of deep brain stimulation electrodes during MR imaging. This in vitro study investigates the relationship between electrode heating and the specific absorption rate (SAR) of several MR images. METHODS In vitro testing was performed by using a 1.5-T MR imaging system and a head transmit-receive coil, with bilateral ...

متن کامل

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions.

PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...

متن کامل

In-vivo Quantitative Measure of Black Hole Severity in Multiple Sclerosis with Gradient Echo Plural Contrast Imaging

Introduction: Among the different types of MS brain lesions observed by MRI, black holes are thought to be most associated with significant tissue destruction including axonal loss [1]. Black holes are usually detected as hypointense areas compared to the normal appearing white matter (NAWM) on T1-weighted (T1w) images generated by conventional turbo-spin-echo (SE) MRI sequences. Unfortunately,...

متن کامل

Spin Echo Amplitude in Biological Tissue with Implications for Vessel Size Imaging

Introduction: Transverse relaxation in living tissue can be used as a probe of tissue structure. Vessel size imaging [1-3] is a realization of this potential: The mean size of microvessels can be evaluated by comparison of the gradient echo and spin echo amplitudes. In practical implementation, it is often convenient to use multiple refocusing pulses (CPMG-type measurement) instead of a single ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 1998