Dissection of the coronary sinus during lead implantation for biventricular pacemaker implantation in patients with advanced heart failure is a serious complication that has occasionally been reported. We report on the clinical outcome and angiographic follow-up in a series of 7 patients with acute major dissection from 103 consecutive attempts (incidence 6.8%). Serial echocardiography was performed in all patients and all underwent follow-up angiography 2-3 months after the procedure. In 1 patient, pericardial extravasation was seen during retrograde venography. Clinical follow-up was uneventful except for one other patient who complained of prolonged chest discomfort for several hours after the procedure. In none of the patients were there signs of pericardial effusion or tamponade demonstrated on echocardiography. Venograms during the procedure and after follow-up were analysed using a quantitative coronary angiography system (CAAS II). Parameters included minimal luminal diameter, diameter stenosis, minimal cross-sectional area and an estimation of the reference diameter. There were no significant differences in all analysed parameters, although in 1 patient a small partial dissection was present. Thus, although dissection of the coronary sinus following lead implantation for biventricular stimulation is not an uncommon complication, it is usually well tolerated. Long-term angiographic follow-up demonstrated no significant vessel damage or vessel remodeling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful implantation of the left ventricular pacing lead in the posterolateral cardiac vein after coronary sinus dissection during biventricular pacing.

Successful Implantation of the Left Ventricular Pacing Lead in the Postero-Lateral Cardiac Vein After Coronary Sinus Dissection During Biventricular Pacing SkevoS SideriS, StefanoS archontakiS, konStantinoS GatzouliS, PolychroniS dilaveriS, ioanniS vlaSeroS, ioanniS kallikazaroS, chriStodouloS StefanadiS State Cardiology Division, First University Department of Cardiology, Hippokration General ...

متن کامل

Localized Aortic Root Dissection Secondary to Contrast Agent Injection: Feasibility of Conservative Follow-up With Echocardiography

Introduction: Iatrogenic aortocoronary dissection (ACD) is a nightmare in interventional cardiology. Although ACD is rarely reported, the real-world prevalence is suspected of being higher due to unreported cases. The right coronary artery (RCA) ostium is involved in the majority of cases, and dissections are usually limited to the aortic sinus in half of the clinical presentat...

متن کامل

Coronary sinus dissection during left ventricular pacing electrode implantation.

Coronary sinus (CS) dissection during biventricular pacing electrode implantation is a complication that rarely develops. A 71-year-old female with recurrent ventricular tachycardia, heart decompensation, and poor left ventricular function because of dilated cardiomyopathy was admitted for the implantation of a cardioverter-defibrillator for biventricular pacing. During the operation, we experi...

متن کامل

Long-Term Performance of Modern Coronary Sinus Leads in Cardiac Resynchronization Therapy

BACKGROUND Cardiac resynchronization therapy (CRT) has become an important pillar of contemporary heart failure therapy. The efficacy of CRT, however, critically relies on proper LV lead placement and performance, which is why data regarding the long-term performance of CS leads are of considerable interest. Available studies are limited by a restricted variety of lead vendors, earlier lead mod...

متن کامل

Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.

OBJECTIVE Biventricular pacing has demonstrated improvement in cardiac function in treating congestive heart failure (CHF). Two different operative strategies (coronary sinus vs. epicardial stimulation) for left ventricular (LV) pacing were compared. METHODS Since April 1999, a total of 86 patients (pts, age: 63+/-10 years) with depressed systolic LV function (mean ejection fraction 24+/-9%),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2004