چکیده

INTRODUCTION This study evaluated the cervical fit of cemented metal-ceramic and In-Ceram implant-supported crowns, before and after the cementing procedure. MATERIALS AND METHODS Twenty crowns cemented on implant abutments are divided into two groups (n = 10): Group 1 -cemented metal-ceramic crowns and group 2 - cemented In-Ceram crowns. The marginal adaptations before and after cementation were evaluated in a comparison microscope with an error of 1 μm. All crowns were cemented with zinc phosphate cement. RESULTS The cervical misalignment of cemented crowns before cementation (52.65 ± 11.83 and 85.73 ± 14.06 μm) was lower than that after cementation (66.80 ± 15.86 and 89.36 ± 22.66 μm). CONCLUSION The cementing procedure interferes with the marginal fit of cemented crowns on implant abutments, with the prosthesis having better adaptation before cementation. Cemented metal-ceramic crowns exhibited better cervical adaptation than In-Ceram crowns cemented before and after the cementing procedure. CLINICAL SIGNIFICANCE The maintenance of gum health and the longevity of prosthetic restorations are closely related to the restoration's marginal integrity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments.

This in vitro study quantified the marginal discrepancy of the implant-to-prosthetic-crown interface on nonsubmerged dental implants restored with either a cemented or a screw-retained approach. Metal-ceramic crowns were fabricated for 20 ITI 4.1 x 10 mm solid-screw titanium implants. Ten implants received octa abutments and screw-retained crowns fabricated on premachined gold cylinders. The re...

متن کامل

The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns

STATEMENT OF THE PROBLEM One disadvantage of cement-retained crowns is the lack of predictable irretrievability. This problem can be overcome through designing a screw access hole in the metal substructure of cement-retained restoration and using porcelain stain to define this area. PURPOSE This study aimed to evaluate the influence of existence of screw access hole on porcelain fracture resi...

متن کامل

New abutment for a screw-retained, implant-supported crown.

The 1-piece, implant-supported abutment and crown, colloquially described as the UCLA abutment, commonly is used to fabricate single, screw-retained crowns. This abutment was designed to allow attachment of the crown directly to the implant and requires a waxing and casting procedure by a laboratory technician. A new prefabricated abutment has been developed that uses a similar approach but doe...

متن کامل

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Comparison of internal fit between implant abutments and cast metal crowns vs laser-sintered crowns.

AIM A common problem related to cemented single crowns is the internal misfit, which may cause inadequate retention, especially when seated on the implant abutment. The aim of this study was to compare the internal fit of Co-Cr crowns using a traditional lost-wax casting technique from laser-sintered Co-Cr alloy crowns. MATERIALS AND METHODS Twelve metallic crowns per each technique were fabr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 2016