Uterobrush method in the detection of endometrial pathology.

نویسندگان

  • C Iavazzo
  • G Vorgias
  • G Mastorakos
  • G Stefanatou
  • A Panoussi
  • A Alexiadou
  • S Plyta
  • C Lekka
  • N Kalinoglou
  • V Dertimas
  • T Akrivos
  • S Fotiou
چکیده

BACKGROUND Endometrial brush cytology is a widely accepted method for the detection of endometrial lesions. The aim of this study was to evaluate the role of cytological sampling using Uterobrush in the screening of endometrial pathology. PATIENTS AND METHODS This is a prospective double-blind study evaluating the efficacy of the Uterobrush method (Cooper Surgical, Trumbull, USA) in the detection of endometrial abnormalities. Endometrial cytology was performed during the period January 2009 to April 2010 in all symptomatic patients that underwent dilatation and curettage. The collected samples were firstly smeared directly onto a glassslide and consequently into Thin-Prep buffer. Cytologic features were evaluated according to the criteria of Tao. The main objective was to evaluate the efficacy of Uterobrush method comparing the results of cytologic and histopathologic examination. RESULTS The sample of the study consisted of 100 women aged 55.8 years (range 38-78 years) with recorded data regarding Uterobrush test and classic histologic examination. Fifty-five patients were postmenopausal. A total of 92% of the samplings were performed by trainees. Endometrial carcinoma was cytologically diagnosed in 8/9 patients, whereas endometrial polyps were diagnosed in 5/34 patients (14.7%). All the patients with simple hyperplasia were correctly diagnosed with the Uterobrush method, whereas the diagnosis of complex hyperplasia with or without atypia was correct in 85.7% and 100% of patients, respectively. Regarding endometrial carcinoma, the sensitivity, specificity, positive and negative predictive values were 88.9%, 100%, 100% and 98.9%, respectively. On the other hand, regarding endometrial polyps, the sensitivity, specificity, positive and negative predictive values were 14.7%, 100%, 100% and 69.5%, respectively. CONCLUSION Uterobrush is a reliable direct intrauterine sampling for detecting endometrial abnormalities especially endometrial carcinoma and hyperplasia, but not endometrial polyps. It is a well-tolerated, easy to use method, which provides generous endometrial sampling without contamination from the endocervix or the vagina.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه قدرت Uterobrush و Pipelle در تشخیص نمونه‌های آندومتر

Abstract Background: Endometrial cancer is the most frequent cancer in the female genital system. Nowadays outpatient diagnostic procedures like pipelle and uterobrush have facilitated the diagnosis and treatment of endometrial cancer in early stages in high-risk patients. This study has been done to compare the accuracy and tissue sufficiency of biopsy by pipelle and uterobrush. Methods: B...

متن کامل

Endometrial Stromal Nodule

The endometrial stromal nodule is a benign tumor composed of differentiated endometrial stromal cells arranged as a well circumscribed nodule with smooth non-invasive margins. They are rare neoplasms, diagnosed in most instances by microscopy. Although nodules are benign in nature, hysterectomy is the treatment of choice to enable evaluation of the tumor margins which are well demarcated in...

متن کامل

I-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions

Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...

متن کامل

Endometrial Ossification Following Repeated Spontaneous Abortions

Endometrial calcification along with ossification is an uncommon clinical entity. Most of the cases are asymptomatic or present with secondary infertility. Endometrial ossification associated with repeated abortions has been reported very infrequently. Here we report a case of endometrial calcification with ossification  due to retained fetal bony tissue in a 38 year old symptomatic female havi...

متن کامل

Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss

Objective: to compare diagnostic values of two dimensional trans-vaginal sonography (TVS) and office hysteroscopy (OH) for evaluation of endometrial pathologies in cases with repeated implantation failure (RIF) or recurrent pregnancy loss (RPL). Methods and Materials: This prospective study was performed in Royan institute from December 2013 to January 2015. TVS was performed before hysteroscop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anticancer research

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 2011