Ischemia detection from morphological QRS angle changes.
نویسندگان
چکیده
In this paper, an ischemia detector is presented based on the analysis of QRS-derived angles. The detector has been developed by modeling ischemic effects on the QRS angles as a gradual change with a certain transition time and assuming a Laplacian additive modeling error contaminating the angle series. Both standard and non-standard leads were used for analysis. Non-standard leads were obtained by applying the PCA technique over specific lead subsets to represent different potential locations of the ischemic zone. The performance of the proposed detector was tested over a population of 79 patients undergoing percutaneous coronary intervention in one of the major coronary arteries (LAD (n = 25), RCA (n = 16) and LCX (n = 38)). The best detection performance, obtained for standard ECG leads, was achieved in the LAD group with values of sensitivity and specificity of [Formula: see text], [Formula: see text], followed by the RCA group with [Formula: see text], Sp = 94.4 and the LCX group with [Formula: see text], [Formula: see text], notably outperforming detection based on the ST series in all cases, with the same detector structure. The timing of the detected ischemic events ranged from 30 s up to 150 s (mean = 66.8 s) following the start of occlusion. We conclude that changes in the QRS angles can be used to detect acute myocardial ischemia.
منابع مشابه
Detection and quantification of acute myocardial ischemia by morphologic evaluation of QRS changes by an angle-based method.
OBJECTIVE In acute myocardial ischemia changes within the QRS complex can add valuable information to that from the repolarization phase. This study evaluates three angles obtained from the main slopes of the R-wave within the QRS complex to assess acute myocardial ischemia. METHODS The QRS angles, denoted by ØR (R-wave angle), ØU (up-stroke angle) and ØD (down-stroke angle), were evaluated i...
متن کاملThe STAFF III ECG database and its significance for methodological development and evaluation.
The development of new techniques for detection and characterization of transient myocardial ischemia has benefited considerably from the STAFF III database, acquired in patients receiving elective prolonged percutaneous transluminal coronary angiography. The present article reviews a range of techniques developed and/or evaluated on the ECG signals of this database, including techniques for ex...
متن کاملHyperQ—new horizons in ischemia detection
Fig. 1. A schematic flow of the production of the HyperQ signal. First, QRS complexes are detected, while rejecting arrhythmias and noisy complexes. The detected QRS complexes are carefully aligned and averaged. The averaged QRS complex is then filtered in the 150to 250-Hz band to Electrocardiogram (ECG)-based ischemia detection is typically based on identifying changes in the ST-T segment, yet...
متن کاملSimulation of high-resolution QRS complex using a ventricular model with a fractal conduction system. Effects of ischemia on high-frequency QRS potentials.
Recent studies have analyzed the high-fidelity surface electrocardiographic signal, and efforts have been made to increase the diagnostic sensitivity of the electrocardiogram by observing its high-frequency components. It was found that the high-frequency (150-250-Hz) electrocardiogram appears to detect evidence of transient ischemia with greater sensitivity than visual inspection of the surfac...
متن کاملTemporal changes in electrocardiographic frontal QRS-T angle and survival in patients with heart failure
BACKGROUND Heart failure (HF) is associated with considerable mortality. The electrocardiographic frontal QRS-T angle is a simple parameter to measure, reflects changes in the direction of the repolarization sequence and predicts outcome in patients with HF. Data regarding temporal changes in the frontal QRS-T angle in patients with HF and its impact on outcome is limited. AIM To evaluate tem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 37 7 شماره
صفحات -
تاریخ انتشار 2016