Corneal biomechanics, refraction, and corneal aberrometry in keratoconus: an integrated study.
نویسندگان
چکیده
Purpose. To evaluate the relationship of corneal biomechanical properties to refraction and corneal aberrometry in keratoconic eyes. Methods. A total of 81 consecutive keratoconic eyes of 81 patients ranging in age from 11 to 58 years were included in the study. Three groups were differentiated according to the severity of keratoconus: mild (37 eyes), moderate (24 eyes), and severe (20 eyes). Visual acuity, refraction, corneal topography, and corneal aberrations were evaluated. In addition, corneal biomechanics were analyzed in relation to two parameters: corneal hysteresis (CH) and corneal resistance factor (CRF). Correlations between these biomechanical factors and the remaining clinical parameters were investigated. Results. CH and CRF in the severe keratoconus group were significantly lower than those in the other two groups (P < or = 0.01). A significant difference in CRF was found between mild and moderate cases (P = 0.04). A moderate correlation was found between the CRF and mean keratometry in the overall sample (r = -0.564). In addition, a significant, strong correlation was found between the spherical-like root mean square (RMS) and the CRF only in the severe keratoconus group (r = -0.655). Multiple regression analysis revealed that CRF correlated significantly with keratometry and the corneal spherical-like RMS (R(2) = 0.40, P < 0.01). Conclusions. The CRF correlates with the magnitude of corneal spherical-like aberrations, especially in severe keratoconus. It should be considered an additional factor in keratoconus grading.
منابع مشابه
Evaluation of Corneal Aberrometry Parameters Before and After Cross-Linking in Patients with Keratoconus
Background and Objective: In the last decade, cross-linking (CXL) has been widely used for treating people with progressive keratoconus. The present study aimed to compare corneal aberrometry parameters before and after CXL in patients with keratoconus. Materials and Methods: In this cross-sectional study, 67 patients with keratoconus referred to Farshchian Sina Medical Education Center, Hamad...
متن کاملClinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study.
PURPOSE To evaluate the clinical outcomes after implantation of the MyoRing (DIOPTEX GmBH, Linz, Austria) by means of femtosecond laser technology in eyes with corneal ectasia. DESIGN Retrospective, consecutive, nonrandomized, case series. PARTICIPANTS A total of 12 eyes of 11 patients with ages ranging from 17 to 50 years were included. All cases were diagnosed with corneal ectasia accordi...
متن کاملویژگیهای بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری
Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...
متن کاملCorneal Collagen Cross-Linking with and without Epithelial Removal: A Contralateral Study with 0.5% Hypotonic Riboflavin Solution
PURPOSE Our main purpose was to compare safety and efficacy in the treatment of progressive keratoconus with "epithelium-on" and "epithelium-off" corneal collagen cross-linking (CXL). Our secondary purpose was to evaluate efficacy of CXL when hypotonic 0.5% riboflavin is used as photosensitizer. METHODS One eye of 20 patients with bilateral progressive keratoconus was randomly treated for "ep...
متن کاملVisual Performance and Optical Quality of Standardized Asymmetric Soft Contact Lenses in Patients With Keratoconus.
Purpose To evaluate the visual performance and optical quality of a standardized asymmetric soft contact lens (SCL) used for correction of higher-order aberrations (HOAs) in eyes with keratoconus. Methods We included 30 eyes (26 patients) with keratoconus (average K: 45.7 ± 2.3 diopters [D]). The patients were subjected to corneal tomography, aberrometry, measurements of manifest refraction a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 4 شماره
صفحات -
تاریخ انتشار 2010