New Quartz Oscillator Switching Method for Nano-Henry Range Inductance Measurements
نویسندگان
چکیده
This article introduces a new method for nano-Henry inductance measurements at the frequency of 4.999 MHz with a single quartz crystal oscillating in the switching oscillating circuit. The real novelty of this method, however, lies in a considerable reduction of the temperature influence of AT-cut crystal frequency change in the temperature range between 0 °C and 50 °C through a switching method which compensates for the crystal's natural temperature characteristics. This allows for the compensation of any influences on the crystal such as the compensation of the non-linear temperature characteristics and the ageing of both the crystal and other oscillating circuit elements, as well as the reduction of the output frequency measurement errors with the help of an additional reference frequency. The experimental results show that the switching method greatly improves the measurement of small inductance changes in the range between μH and nH, allowing as a result high-precision measurements (~0.35 fH) in this range.
منابع مشابه
High Resolution Switching Mode Inductance-to-Frequency Converter with Temperature Compensationti
This article proposes a novel method for the temperature-compensated inductance-to-frequency converter with a single quartz crystal oscillating in the switching oscillating circuit to achieve better temperature stability of the converter. The novelty of this method lies in the switching-mode converter, the use of additionally connected impedances in parallel to the shunt capacitances of the qua...
متن کاملGreatly Improved Small Inductance Measurement Using Quartz Crystal Parasitic Capacitance Compensation
Generally, quartz crystal inductance frequency pulling in oscillators is very low and therefore is not often used in practice. The new method of improving frequency pullability uses inductance to compensate for quartz stray capacitances. To this end, a special AT fundamental quartz crystal working near the antiresonance frequency is selected. By modifying its equivalent circuit with load induct...
متن کاملHigh-Precision Hysteresis Sensing of the Quartz Crystal Inductance-to-Frequency Converter
A new method for the automated measurement of the hysteresis of the temperature-compensated inductance-to-frequency converter with a single quartz crystal is proposed. The new idea behind this method is a converter with two programmable analog switches enabling the automated measurement of the converter hysteresis, as well as the temperature compensation of the quartz crystal and any other circ...
متن کاملCompatibility of the Active Inductance Double Resonance Quartz Oscillator with Q-MEMS Temperature Sensor
Low-frequency double-resonance quartz crystal oscillator circuit was developed with active inductance aiming the quick start-up in the intermittent operation on the sensor circuit and DC isolation using a Q-MEMS sensing crystal HTS-206. Allan standard deviation indicated 5 × 10−12, showing short range stability of the sensor circuit sufficient for the ubiquitous environmental sensor network.
متن کاملNext Generation AT-Cut Quartz Crystal Sensing Devices
Generally, AT-cut quartz crystals have a limited scope of use when it comes to high-precision measurement of very small impedance changes due to their nonlinear frequency-temperature characteristics in the range between 0 °C and 50 °C. The new method improving quartz oscillator frequency-temperature characteristic compensation is switching between two impedance loads. By modifying the oscillato...