Changes in haematology measurements with the Sysmex XT-2000iV during storage of feline blood sampled in EDTA or EDTA plus CTAD.

نویسندگان

  • Fanny Granat
  • Anne Geffré
  • Nathalie Bourgès-Abella
  • Jean-Pierre Braun
  • Catherine Trumel
چکیده

In veterinary medicine a complete blood cell count (CBC) cannot always be performed within 24 h as usually recommended, particularly for specimens shipped to a reference laboratory. This raises the question of the stability of the variables, especially in ethylenediamine tetra-acetic acid (EDTA) feline blood specimens, known to be prone to in vitro platelet aggregation. Citrate, theophylline, adenosine and dipyridamole (CTAD) has been reported to limit platelet aggregation in feline blood specimens. The aim of this study was to measure the stability of the haematological variables and the platelet aggregation score in EDTA and EDTA plus CTAD (EDCT) feline blood specimens during 48 h of storage at room temperature. Forty-six feline EDTA and EDCT blood specimens were analysed with a Sysmex XT-2000iV analyser, and the platelet count and score of platelet aggregation were estimated immediately and after 24 and 48 h of storage. A significant increase in mean corpuscular volume, haematocrit, reticulocyte and eosinophil counts, and a significant decrease in mean corpuscular haemoglobin concentration and monocyte count were observed. Haemoglobin, mean corpuscular haemoglobin, and red blood cell, white blood cell, neutrophil and lymphocyte counts remained stable. Changes in reticulocyte indexes with time (low fluorescence ratio, medium fluorescence ratio, high fluorescence ratio and immature reticulocyte fraction) were not significant. Changes were generally more pronounced in EDTA than in EDCT. Platelet aggregation decreased markedly in initially highly aggregated EDTA specimens, and increased slightly in initially non- or mildly-aggregated EDTA or EDCT specimens. Platelet counts increased and decreased, or remained stable, respectively. CTAD can reduce storage-induced changes of the haematological variables in feline samples, thus improving the reliability of a CBC and limiting clinical misinterpretations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective prevention of pseudothrombocytopenia in feline blood samples with the prostaglandin I2 analogue Iloprost

BACKGROUND In vitro platelet aggregation in feline blood samples is a well-known phenomenon in veterinary clinical laboratories resulting in high numbers of pseudothrombocytopenia. Several attempts have been made to prevent or dissolve platelet aggregates in feline blood samples and to increase the reliability of feline platelet counts. Prostaglandin I2 (PGI2) is the most powerful endogenous in...

متن کامل

Optimized gating and reference ranges of reticulated platelets in dogs for the Sysmex XT-2000iV

BACKGROUND Canine reticulated platelets (r-PLTs) i.e., juvenile PLTs reflecting thrombopoiesis can be measured automatically with the hematology analyzer Sysmex XT-2000iV using manual gating options. However, the impact of interferences on r-PLT measurements performed with the gates published previously (Pankraz et al., Vet Clin Path 38:30-38, 2009; Gelain et al., High fluorescent platelets fra...

متن کامل

Optimized plasma preparation is essential to monitor platelet-stored molecules in humans

Platelets store a plethora of different molecules within their granules, modulating numerous pathways, not only in coagulation, but also in angiogenesis, wound healing, and inflammatory diseases. These molecules get rapidly released upon activation and therefore represent an easily accessible indirect marker for platelet activation. Accurate analysis of platelet-derived molecules in the plasma ...

متن کامل

Rate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative

Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...

متن کامل

Effects of genistein on melanosis and microbial quality of Litopenaeus vannamei during ice storage

Utilization of genistein as a natural inhibitor was studied alone and in combination with conventional treatments on melanosis and microbial quality of fresh L. vannamei during 10 days ice storage. Treatments were as followed: A (dipping samples in distilled water), B (dipping in 1.25 % sodium metabisulphite solution), C (dipping in 0.01 % genistein + 2% glycerol solution), D (dipping in 0.1 % ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of feline medicine and surgery

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2013