Automated kinetic method for D-3-hydroxybutyrate in plasma or serum.

نویسندگان

  • C H McMurray
  • W J Blanchflower
  • D A Rice
چکیده

This assay for 3-hydroxybutyrate in plasma or serum, based on kinetic initial-rate techniques, has been optimized with respect to initial rate and linearity as follows: pH 8.5, hydroxybutyrate dehydrogenase 62.5 U/L, and NAD+ concentration 20 mmol/L. We have used the assay satisfactorily with both the Gilford 103 and Hitachi 705 discrete analyzers, obtaining results that compare well with those by a segmented-flow method. Within-assay precision (CV) varied from 7.8 to 0.6%, depending on both the analyzer used and on the concentration of 3-hydroxybutyrate. Analytical recovery was also dependent on 3-hydroxybutyrate concentration, varying from 99% at 2 mmol/L to 91% at 9.5 mmol/L. Lactate dehydrogenase/lactate interference in this direct assay is eliminated by incorporating oxalate in the assay reagents. Hydrazine, commonly used in equilibrium methods of analysis for 3-hydroxybutyrate, produced no significant advantage in this assay and was omitted. The mixed reagents for the assay are stable at 4 degrees C for at least a week. The advantages of analysis for this metabolite may now be realized, so that clinical and subclinical ketosis can be identified in humans and animals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic measurement of the combined concentrations of acetoacetate and beta-hydroxybutyrate in serum.

This is an automated method for the kinetic measurement of the combined concentrations of acetoacetate and beta-hydroxybutyrate in a single channel of the "Multistat III" centrifugal analyzer. Acetoacetate is first reduced with high concentrations of NADH by catalysis with 3-hydroxybutyrate dehydrogenase (EC 1.1.1.30). This reaction mixture is diluted with excess NAD+. The endogenous beta-hydro...

متن کامل

Multipoint kinetic method for simultaneously measuring the combined concentrations of acetoacetate-beta-hydroxybutyrate and lactate-pyruvate.

This is a multipoint kinetic method for simultaneously determining acetoacetate (AcAc) plus beta-hydroxybutyrate and lactate plus pyruvate in a single cuvette of the Multistat III centrifugal analyzer. In the first step, AcAc and pyruvate are completely reduced, using 3-hydroxybutyrate dehydrogenase (EC 1.1.1.30) and lactate dehydrogenase (EC 1.1.1.27) in the presence of excess NADH at pH 7.5, ...

متن کامل

A kinetic spectrophotometric assay for rapid determination of acetoacetate in blood.

We describe an automated kinetic assay for acetoacetate in blood. Acetoacetate is enzymatically reduced to D-beta-hydroxybutyrate and the reaction is monitored for 60 s with a reaction-rate analyzer. This technique allows low concentrations of acetoacetate to be measured with good precision and overcomes many of the problems associated with other automated techniques. Our studies on the stabili...

متن کامل

Coupling of glucose-6-phosphate dehydrogenase and hemoglobin S screening to automated determinations of blood group and type.

1.Elliott, B. A., and Wilkinson, J. H., Serum “a-hydroxybutyrate dehydrogenase” in myocardial infarction and in liver disease. Lancet i, 698(1961). 2. Elliott, B. A., Jepson, E. M., and Wilkinson, J. H., Serum ahydroxybutyrate dehydrogenase-a new testwith improved specificity for myocardial lesions. Gun. Sci. 23, 305(1962). 3. Coodley, E. L., Evaluation of enzyme diagnosis in myocardial infarct...

متن کامل

Optimized Kinetic Method for Automated Determination of $-Hydroxybutyrate

We reportthe development of an optimizedmethod for determination of serum f3-hydroxybutyrate. We first developed the assay for use in the Technicon RA-1000, then modified it for the COBAS FARA, making several notable improvements. Several important factors considered individually by other authors have for the first time been coalesced in one method. The optimized reaction mixture contains 100 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 1984