Determination of Total Iodine in Infant Formula and Adult/ Pediatric Nutritional Formula by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Collaborative Study, Final Action 2012.15.
نویسندگان
چکیده
A collaborative study was conducted to determine total iodine in infant formula and adult/pediatric nutritional formula by inductively coupled plasma-MS (ICP-MS) using AOAC First Action Official Method(SM) 2012.15. The purpose of this study was to evaluate the method's intralaboratory and interlaboratory performance and submit the results to AOAC INTERNATIONAL for adoption as a Final Action Official Method for the determination of total iodine in infant formula and adult/pediatric nutritional formula. Upon providing acceptable results for practice samples National Institute of Standard and Technology (NIST) Standard Reference Material (SRM) 1849a and a low-fat adult nutritional powder, 13 laboratories analyzed seven various infant and adult nutritional products including a blind duplicate of each. Products were chosen with varying levels of iodine and included low-fat, soy-based, and milk-based formulas and NIST SRM 1849a. Random identification numbers were assigned to each of the seven fortified test materials. Digestion of the test samples occurred using a potassium hydroxide solution in an oven or open-vessel microwave system. Iodine was stabilized with ammonium hydroxide and sodium thiosulfate after digestion. The solutions were brought to volume followed by filtration. The filtrates were then analyzed by ICP-MS after dilution. Results for all seven test samples met all the AOAC Standard Method Performance Requirements (SMPR(®) 2012.008) guidelines. The RSDr ranged from 0.77 to 4.78% and the RSDR from 5.42 to 11.5%. The Horwitz ratio (HorRat) for each result was excellent, ranging from 0.35 to 1.31%. The results demonstrate that the method is fit-for-purpose to determine iodine in infant formula and adult/pediatric nutritional formula.
منابع مشابه
Determination of Chromium, Selenium, and Molybdenum in Nutritional Products by ICP-MS Authors
An ICP-MS validated method for the rapid determination of chromium (Cr), selenium (Se), and molybdenum (Mo) in infant formula and adult nutritional products was successfully transferred from the Agilent 7500cx ICP-MS to the Agilent 7700x ICP-MS, and from lab 1 to lab 2, respectively. The key advantage of the method is that all samples can be analyzed using a single-cell gas mode (helium mode) t...
متن کاملSpeciation and isotope pattern deconvolution for inductively coupled plasma-mass spectrometry quantitative studies of mineral metabolism and supplementation*
Human breast milk can be considered as “ideal” food for the correct development of newborn babies and, for those that are not breast-fed, formula milk has to be used instead. Ideally, the composition of such formula milk preparations should closely resemble that of maternal human milk. Considerable differences between both in the total content of trace elements such as Fe, Cu, Se, Zn, and I and...
متن کاملApplication of inductively coupled plasma/mass spectrometry for the measurement of chromium, selenium, and molybdenum in infant formula and adult nutritional products: First Action 2011.19.
An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formula and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 fo...
متن کاملApplication of ICP-MS, INAA and RNAA to the determination of some “difficult” elements in infant formulas
In this work a determination of selected elements in the infant formulas commercially available on the Polish market was done. 14 different materials (milk-based formulas and grain porridges) were analyzed. Both, inductively coupled plasma mass spectrometry (ICP-MS) and instrumental neutron activation analysis (INAA) were applied for the determination of As, Cr, Fe and Se, which are recognized ...
متن کاملUrinary iodine: comparison of a simple method for its determination in microplates with measurement by inductively-coupled plasma mass spectrometry
The aim of our study was to develop and validate an inexpensive, rapid, easy to use quantitative method to determine urinary iodine without major procurement costs for equipment. The rationale behind introducing this method is the increasing demand for urinary iodine assessments. Our study included 103 patients (76 female, 27 male), age (arithmetic mean) 52 ± 17.3 years. Urinary iodine was dete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 98 5 شماره
صفحات -
تاریخ انتشار 2015