Magnetic field perturbation of neural recording and stimulating microelectrodes.
نویسندگان
چکیده
To improve the overall temporal and spatial resolution of brain mapping techniques, in animal models, some attempts have been reported to join electrophysiological methods with functional magnetic resonance imaging (fMRI). However, little attention has been paid to the image artefacts produced by the microelectrodes that compromise the anatomical or functional information of those studies. This work presents a group of simulations and MR images that show the limitations of wire microelectrodes and the potential advantages of silicon technology, in terms of image quality, in MRI environments. Magnetic field perturbations are calculated using a Fourier-based method for platinum (Pt) and tungsten (W) microwires as well as two different silicon technologies. We conclude that image artefacts produced by microelectrodes are highly dependent not only on the magnetic susceptibility of the materials used but also on the size, shape and orientation of the electrodes with respect to the main magnetic field. In addition silicon microelectrodes present better MRI characteristics than metallic microelectrodes. However, metallization layers added to silicon materials can adversely affect the quality of MR images. Therefore only those silicon microelectrodes that minimize the amount of metallic material can be considered MR-compatible and therefore suitable for possible simultaneous fMRI and electrophysiological studies. High resolution gradient echo images acquired at 2 T (TR/TE = 100/15 ms, voxel size = 100 x 100 x 100 microm3) of platinum-iridium (Pt-Ir, 90%-10%) and tungsten microwires show a complete signal loss that covers a volume significantly larger than the actual volume occupied by the microelectrodes: roughly 400 times larger for Pt-Ir and 180 for W, at the tip of the microelectrodes. Similar MR images of a single-shank silicon microelectrode only produce a partial volume effect on the voxels occupied by the probe with less than 50% of signal loss.
منابع مشابه
Magneto-Thermo-Elastic Stresses and Perturbation of Magnetic Field Vector in a Thin Functionally Graded Rotating Disk
In this paper, a semi-analytical solution for magneto-thermo-elastic problem in an axisymmetric functionally graded (FG) hollow rotating disk with constant thickness placed in uniform magnetic and thermal fields with heat convection from disk’s surfaces is presented. Solution for stresses and perturbation of magnetic field vector in a thin FG rotating disk is determined using infinitesimal theo...
متن کاملMagneto-Thermo-Elastic Stresses and Perturbation of the Magnetic Field Vector in an EGM Rotating Disk
In this article, the magneto-thermo-elastic problem of exponentially graded material (EGM) hollow rotating disk placed in uniform magnetic and temperature fields is considered. Exact solutions for stresses and perturbations of the magnetic field vector in EGM hollow rotating disk are determined using the infinitesimal theory of magneto-thermo-elasticity under plane stress. The material properti...
متن کاملStress Analysis of Magneto Thermoelastic and Induction Magnetic Filed in FGM Hallow Sphere
In this paper a closed form solution for one-dimensional magnetothermoelastic problem in a functionally graded material (FGM) hollow sphere placed in a uniform magnetic field and temperature field subjected to an internal pressure is obtained using the theory of magnetothermoelasticity. Hyper-geometric functions are employed to solve the governing equation. The material properties through the g...
متن کاملRapid modulation of local neural activity by controlled drug release from polymer-coated recording microelectrodes.
We demonstrate targeted perturbation of neuronal activity with controlled release of neurochemicals from conducting polymer-coated microelectrodes. Polymer coating and chemical incorporation are achieved through individually addressable electrodeposition, a process that does not compromise the recording capabilities of the electrodes. Release is realized by the application of brief voltage puls...
متن کاملNanofluid Flow in a Semi-porous Channel in the Presence of Uniform Magnetic Field
In this paper, the problem of laminar nanofluid flow in a semi-porous channel is investigated analytically using Homotopy Perturbation Method (HPM). This problem is in the presence of transverse magnetic field. Here, it has been attempted to show the capabilities and wide-range applications of the Homotopy Perturbation Method in comparison with the numerical method in solving such problems. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 52 8 شماره
صفحات -
تاریخ انتشار 2007