Application of global sensitivity analysis to FDS simulations of large LNG fire plumes

نویسندگان

  • Adrian Kelsey
  • Simon Gant
چکیده

In 2009, a series of experiments were conducted by Sandia National Laboratories at a large-scale test complex in Albuquerque, New Mexico, in which Liquefied Natural Gas (LNG) was released onto the surface of a large pool of water and then ignited. These experiments involved the largest releases of LNG ever performed, with the spills covering a circular area up to 83 m in diameter. In the test with the largest LNG release rate, unexpected behaviour was observed. The flames did not cover the entire area of the LNG spill, but were instead limited to a smaller region, around 50 m in diameter. The height of the flames was also greater than expected from previous large-scale tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pricing of Natural Gas Feed stock Based on Financial Assessment of Small-Scale LNG Plants in Iran

Export of liquefied natural gas (LNG) is one of the basic needs of the Iranian oil, gas and petrochemical industry due to the severe sanctions conditions in Iran, restrictions on export of natural gas through pipelines and increased use of LNG in the energy basket of different countries. However, in recent years, despite some attempts to produce this strategic product, no concrete results have ...

متن کامل

A New Investigation on Tunnel Pool Fire Phenomenon Using CFD Technique

In this study, the amount of generated pool fire, as a result of the release of chemicals in the case of an accident in tunnels, was simulated and the results were compared to the experimental data. At first, various amounts of spatial resolution (R*) were considered to compare the existing experimental data at different heights at the upstream, downstream and above the pool fire...

متن کامل

Numerical simulations of LNG vapor dispersion in Brayton Fire Training Field tests with ANSYS CFX.

Federal safety regulations require the use of validated consequence models to determine the vapor cloud dispersion exclusion zones for accidental liquefied natural gas (LNG) releases. One tool that is being developed in industry for exclusion zone determination and LNG vapor dispersion modeling is computational fluid dynamics (CFD). This paper uses the ANSYS CFX CFD code to model LNG vapor disp...

متن کامل

Title of Document : Flame Extinction and Air Vitiation Effects In FDS In Poorly Ventilated Compartment Fires

Title of Document: Flame Extinction and Air Vitiation Effects In FDS In Poorly Ventilated Compartment Fires Zhixin Hu, Master Thesis, 2005 Directed by: Arnaud Trouvé, Associate Professor Department of Fire Protection Abstract: Compartment fires with different ventilation conditions exhibit different dynamical behaviors, ranging from steady fuel-limited fires to unsteady airlimited fires. Numeri...

متن کامل

Integrating Fire, Structure and Agent Models

A state-of-the-art integrated environment was created to study interaction among fire, structure and agent models in a fire evacuation from a typical office building. For the fire simulations NIST large-eddy simulation code Fire Dynamics Simulator (FDS) was used. The code is based on a mixture fraction model. FDS provided time resolved temperature, CO, CO2, soot distribution in the building. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014