Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

نویسندگان

  • J A Nelson
  • D B Hawkins
چکیده

Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions may not accurately reflect in situ hearing aid performance. This study compared the real-ear aided response (REAR) and real-ear insertion response (REIR) for a body-worn hearing aid using the substitution method and an off-line equalization modified pressure method with three different loudspeaker locations (0 degrees and 45 degrees at head level and 0 degrees at body hearing aid level) and two reference microphone positions (over-the-ear [OTE] and next to the body hearing aid microphone). Results indicated that each of the responses was affected by changes in loudspeaker and reference microphone location. If the substitution method measured from 0-degrees azimuth at head level is considered to be the most realistic representation of hearing aid performance, the closest agreement with body-worn hearing aids was obtained with the modified pressure method when the loudspeaker was located at 0-degrees azimuth at head level and the reference microphone was located over the ear. If the clinician uses the modified pressure method and desires to approximate results with the substitution method, correction values are needed for REAR measurements but not for REIR measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of reference microphone location and loudspeaker azimuth on probe tube microphone measurements.

The effects of loudspeaker azimuth and reference microphone location on probe tube microphone measures were assessed. The real ear unaided response (REUR), real ear aided response (REAR), and real ear insertion response (REIR) were obtained on a KEMAR. Aided measures were obtained with both a behind-the-ear and an in-the-ear hearing aid. All three measurements were affected by changes in the lo...

متن کامل

Fabrication and investigation of a transparent and flexible loudspeaker and microphone based on carbon nanotube

Transparent acoustic sensors and actuators are a new generation of acoustic transducers that can create an evolution in the microphone and loudspeakers industries. These transducers with properties like transparency, flexibility, flatness, very low weight and thickness have a great potential for various applications like public speakers, active noise cancelation systems, displays, cell phones a...

متن کامل

Free-field Calibration of Mems Microphone Array Used for Acoustic Holography

The paper deals with method and methodology for calibration of the whole microphone array without the need of dismounting of each microphone and calibrating separately. This situation is usual with MEMS transducers which cannon be dismantled from the frame. The method is based on generation of spherical acoustic wave propagating in free-field and synchronously received by all microphones in the...

متن کامل

Experimental Investigations of Different Microphone Installations for Active Noise Control in Ducts

A request on ventilation systems today is the feature of a low noise level. A common method to attenuate ventilation noise is to use passive silencers. However, such silencers are not suitable for the lowest frequencies and one solution is to use active noise control (ANC) to increase the noise attenuation in the low frequency range. Normally when using a feedforward ANC system to attenuate duc...

متن کامل

Dynamical Interactions with Electronic Instruments

This paper examines electronic instruments that incorporate dynamical systems, where the behaviour of the instrument depends not only upon the immediate input to the instrument, but also on the past input. Five instruments are presented as case studies: Michel Waisvisz’ Cracklebox, Dylan Menzies’ Spiro, no-input mixing desk, the author’s Feedback Joypad, and microphone-loudspeaker feedback. Lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1994