Errors in the Measurement of Root Pressure and Exudation Volume Flow Rate Caused by Damage during the Transfer of Unsupported Roots between Solutions.

نویسنده

  • D M Miller
چکیده

Plants of Zea mays were grown with their roots confined to growing tubes, consisting of cylindrical or spherical glass tubes fitted at the bottom with a stopcock. Nutrient solution was circulated past the roots, and when a plant was 21 to 25 days old, the stopcock was closed, the root excised from the plant and connected to an apparatus which measured root pressure and exudation volume flow rate. The stopcock was opened and solution was again circulated through the growing tube without dropping the level of the liquid bathing the root in the process. Measurements of pressure and flow rate were made continuously during a period in which the solution was replaced, first by draining and refilling the tube in situ, and second by replacing the growing tube with a beaker of solution. Both these manipulations caused at least temporary and frequently permanent drops in root pressure and flow rate. Plants were also grown in cylindrical tubes with a support medium of either glass beads or Raschig rings which filled the growing tubes. It is shown that the solution bathing these roots could be repeatedly replaced by draining and refilling with no visible effect on the measurements. It is recommended, therefore, that in future, support be provided for the roots of all experimental plants grown by solution culture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal performance enhancement of automobile radiator using water-CuO nanofluid: an experimental study

In the present paper, the effect of water-CuO nanofluid on the radiator heat transfer of an automobile, Peugeot 405 XU7 engine type is investigated experimentally. The experiments are carried out for the radiator water (water-ethylene glycol with a volume fraction of 80-20, respectively) as a base fluid and water-CuO nanofluid with the volume fraction of 0.5% and 1%. Sodium Dodecyl Sulfate (SDS...

متن کامل

Investigation of Laminar Pulsating Nanofluid Flow and Heat Transfer in a Rectangular Channel

In this study, two-dimensional pulsating unsteady flow of nanofluid through a rectangular channel with isothermal walls is investigated numerically. The set of resultant algebraic equations is solved simultaneously using SIMPLE algorithm to obtain the velocity and pressure distribution within the channel. The effects of several parameters, such as volume fraction of different nanoparticles, Rey...

متن کامل

EVALUATION OF PRESSURE EFFECT ON HEAT TRANSFER COEFFICIENT AT THE METAL- MOLD INTERFACE FOR CASTING OF A356 AL ALLOY

Abstract: During solidification and casting in metallic molds, the heat flow is controlled by the thermal resistance at the casting-mold interface. Thus heat transfer coefficient at the metal- mold interface has a predominant effect on the rate of heat transfer. In some processes such as low pressure and die-casting, the effect of pressure on molten metal will affect the rate of heat transfer a...

متن کامل

اثر ویژگی های رسوب بر تجمع و نرخ انتقال فلزات سنگین در درختان مانگرو (مطالعه موردی: خلیج نایبند و جزیره قشم)

In this paper, the accumulation of heavy metals of Nickel (Ni) and Vanadium (V) was measured in habitat sediments, mangrove roots and leaves (Avicennia marina). Besides, the transfer of Ni and V from the sediment to root and to the leaves in Nayband Bay and Qeshm Island were studied. The samples were gathered by Systematic-random Sampling using selective transects at 16 stations at the end of m...

متن کامل

The Experimental Study of Nanoparticles Effect on Thermal Efficiency of Double Pipe Heat Exchangers in Turbulent Flow

In this work, the characteristics of flow and heat transfer of a fluid containing nano particles of aluminum oxide with the water volume fraction (0.1-0.2-0.3)(V/V) percent of the reports. The overall heat transfer coefficient, heat transfer and the average heat transfer fluid containing nano water - aluminum oxide in a horizontal double pipe counter flow heat exchanger under turbulent flow con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plant physiology

دوره 85 1  شماره 

صفحات  -

تاریخ انتشار 1987