Application of a commercial kit for detection of PCR products to quantification of human immunodeficiency virus type 1 RNA and proviral DNA.
نویسندگان
چکیده
Quantitative tests for human immunodeficiency virus type 1 (HIV-1) RNA in plasma and proviral DNA in peripheral blood mononuclear cells (PBMC) provide valuable information on the status of HIV-1 infection. This paper describes tests that were carried out with commercially available materials and an enzyme-linked immunosorbent assay reader for detecting spectrophotometric changes. Samples consisted of 100 microliters of plasma or 200,000 PBMC. The procedure involved sample preparation, PCR-based amplification with the primer pair SK39 (biotinylated at the 5' end) and SK38, hybridization of the cDNA PCR product to an RNA probe, capture of the RNA-DNA hybrid on a solid phase by means of strepavidin, binding to an alkaline phosphatase-conjugated antibody directed against RNA-DNA hybrids, and incubation with p-nitrophenylphosphate. Spectrophotometric changes were recorded at four intervals over a period of 20 h. The inclusion of HIV-1 RNA or proviral DNA standards in each run was an integral part of the procedure. The dynamic ranges afforded by these assays--500 to 1 million RNA copies per ml and 10 to 5,000 proviral DNA copies per 10(6) PBMC--were applicable to most plasma specimens and to all PBMC specimens from HIV-1-infected patients. Correlations of log-transformed HIV-1 RNA and proviral DNA concentrations with those found by reference methods were, respectively, 0.88 and 0.80. The between-run coefficients of variation for the detection method were < or = 25% (range, 9.1 to 24.7) and < or = 15% (range, 10.9 to 15.1), respectively, for HIV-1 RNA and proviral DNA. The reproducibility of the overall procedure for HIV-1 RNA in plasma (including sample preparation, amplification, and detection) was given by a duplicate standard deviation of log10 copies per ml of 0.11. Thus, the method was sufficiently precise to allow the detection of fourfold changes in plasma HIV-1 RNA concentrations, with a power of 0.95.
منابع مشابه
A Reverse transcription-PCR assay for detection of type A influenza virus and differentiation of avian H7 subtype
Abstract : Avian influenza virus (AIV) infection is a major cause of influenza mortality in birds and can cause human mortality and morbidity. Although the risk of infection with avian influenza virus (AIV) is generally low for most people, the pathogenic virus can cross the species barrier and acquires the ability to infect and be transmitted among the human population; therefore the ra...
متن کاملتعیین کمی بار ویروسی هپاتیت C با استفاده از روش Real-Time PCR In-House در بیماران آلوده به هپاتیت C در شهرستان خرم آباد
Background : Molecular diagnostic methods are among major tools in management of hepatitis C virus (HCV) in infected patients. Many studies have shown that viral load is associated with stage of infection and response to treatment. Therefore, the evaluation and quantification of viral load is very important. The goal of this study is implementation of inexpensive, yet accurate method for quanti...
متن کاملHuman immunodeficiency virus type 1 (HIV-1) proviral DNA load in purified CD4+ cells by LightCycler® Real-time PCR
BACKGROUND The human immunodeficiency virus type 1 (HIV-1) proviral DNA persists in infected cells, even after prolonged successful HAART. In the present study, a relative quantification assay of HIV-1 proviral DNA by LightCycler real-time PCR based on SYBR Green I detection was developed in comparison to the number of purified CD4+ cells as estimated by the quantification of the beta-globin ge...
متن کاملQuantification of human immunodeficiency virus type 1 proviral load by a TaqMan real-time PCR assay.
Proviral human immunodeficiency virus type 1 (HIV-1) DNA could be a useful marker for exploring viral reservoirs and monitoring antiretroviral treatment, particularly when HIV-1 RNA is undetectable in plasma. A new technique was developed to quantify proviral HIV-1 using a TaqMan real-time PCR assay. One copy of proviral HIV-1 DNA could be detected with 100% sensitivity for five copies and the ...
متن کاملDesign a Real Time PCR with SYBR Green for quantification of HTLV-1 proviral load for blood donors
Abstract Background and Objectives In Iran, Khorasan province is an endemic area for HTLV-1 virus. Considering the inability of serological tests to determine HTLV-1 in window period, their failure to confirm the indetermination results of western blot, and given the probability for HTLV-1 transfusion transmission, a SYBR green-based Real Time PCR was set to measure the HTLV-1 proviral load. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 34 2 شماره
صفحات -
تاریخ انتشار 1996