Cochlear implants help regain the auditory sense in cases where the cochlea is not able to transform the sound signals into electric stimulation for the auditory cortex. By their very nature, cochlear implants require a calibration process, which is often based on the electrically evoked stapedius reflex threshold (ESRT), since it very well correlates with a person's most comfortable loudness level[PZS + 09]. During the ESRT-based calibration process, the implant stimulates the cochlea with increasing currents until the stapedius muscle contraction can be observed visually. The calibration process described above yields a first, rough implant adjustment, which requires an additional, extensive calibration procedure a few weeks after the implantation. The goal of this project is the development of an autonomous calibration scheme that is constantly monitoring and occasionally re-calibrating the implant. To this end, the system utilizes the electromyographic (EMG) signals that it directly derives at the stapedius muscle by means of specific electrodes. The system basically correlates the external (objective) loudness and the observable stapedius muscle activity, and correlates them with the expected, pre-defined stapedius activity. Too large a difference between the expected and observable stapedius activity, the system triggers an adaptation cycle of the implant's gain factors. The processing of the EMG signals of the stapedius muscle employs a series of three filters: (1) a 4th-order band-pass filter with corner frequencies of 30 and 500 Hz for removing steady components and high-frequency noise, (2) a rectifier, and (3) a 4th-order low-pass filter with a corner frequency of 2 Hz for extracting the EMG signal's envelope. In its subsequent processing stages, the system considers this envelope as the physical activity of the stapedius muscle[SRSV10]. This system has undergone a series of different tests. Since no solid EMG signal data 1
منابع مشابه
Automatic Detection of the Electrical Elicited Stapedius Reflex by Evaluation of Its Electromyographic Signals
This paper provides a first preliminary description of the dependencies between the stapedius muscle’s behavior and its neuronal activation with the adjustment of cochlear implants in mind. For that, stapedial electromyography (EMG) data are compared with EMG data which were derived from the quadriceps femoris muscle. The rationale behind is, that the stapedius muscle is classified as a striate...
متن کاملThe Relationship Between Reaction Time of Electrical Stapedius Reflex and Auditory Performance in Cochlear-Implanted Children
Background: A common concern in some cochlear-implanted children is the lack of desired progress in auditory and listening skills. Such a concern remains despite proper verbal processor programming, additional disabilities, and continuous participation in hearing rehabilitation programs. A more detailed assessment of pathways and centers of the auditory processing at the lower end of the brain ...
متن کاملAutomatic Sleep Stages Detection Based on EEG Signals Using Combination of Classifiers
Sleep stages classification is one of the most important methods for diagnosis in psychiatry and neurology. In this paper, a combination of three kinds of classifiers are proposed which classify the EEG signal into five sleep stages including Awake, N-REM (non-rapid eye movement) stage 1, N-REM stage 2, N-REM stage 3 and 4 (also called Slow Wave Sleep), and REM. Twenty-five all night recordings...
متن کاملThe Stapedius Reflex: Beyond its Visually Observable Binary On/Off Behavior
Visually, the stapedius reflex is an on/off phenomenon that either appears or not. However, this paper presents some additional data that suggests a rather continuous stapedius reflex that above a certain threshold, leads to progressively increasing forces of the stapedius muscle. With this effect, the stapedius reflex can be used not only for the initial calibration of the cochlear implant’s s...
متن کاملStapedius reflex measurements during surgery for cochlear implantation in children.
Electrically evoked stapedius reflex measurements were obtained in 19 children during surgery for cochlear implantation. They all received the Nucleus device. Stapedius reflexes could be elicited in all the children with congenital deafness but not in all the children with an etiology of meningitis. The intraoperative stapedius reflex thresholds were compared with postoperative values obtained ...