Residual wrist pain after volar locking plate fixation of distal radius fractures.

نویسندگان

  • Shigeru Kurimoto
  • Masahiro Tatebe
  • Takaaki Shinohara
  • Tetsuya Arai
  • Hitoshi Hirata
چکیده

A prospective multicenter clinical study evaluated, using the Hand20 and hand diagram, the disability, incidence, location, and predictive factors of residual wrist pain 18 months after volar locking plate fixation of distal radius fracture in 122 patients. The average Hand20 score and numeric rating scores for pain were 13.1 +/- 18.2 and 2.1 +/- 23, respectively. Fifty-seven patients indicated that they had pain. Among those patients, 25 had ulnar pain and 45 had radial pain. The incidence of radial-sided wrist pain was higher than ulnar-sided wrist pain. Logistic regression analysis showed that female sex and intra-articular fracture significantly correlated with radial-sided wrist pain. Volar locking plate fixation maintained anatomical reduction; however, a significant number of patients complained of residual wrist pain.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes

BACKGROUND The objective of this study was to evaluate clinical and radiographic outcomes of volar plate versus intramedullary nailing for fixation of distal radius fractures. MATERIAL AND METHODS This retrospective study included 64 patients with extra-articular and simple intra-articular fractures of the distal radius who underwent intramedullary fixation using volar locking plate (n=35, mean...

متن کامل

Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.

Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...

متن کامل

Comparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures

Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been succe...

متن کامل

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 78 5  شماره 

صفحات  -

تاریخ انتشار 2012