Preparation of bronchoalveolar lavage fluid with microscope slide smears.
نویسندگان
چکیده
The method of preparation of bronchoalveolar lavage fluid (BALF) for cytological examination can significantly affect the results of cellular quantitation. Investigations have shown that cytocentrifugation leads to an underestimation of the number of lymphocytes and membrane filter preparation to an underestimation of the number of neutrophils. As a simple alternative to these two techniques, BALF cells could be prepared by the microscope slide smear technique, which is familiar as the means for preparing peripheral blood for differential counts. In order to compare cell differentials determined by microscope slide technique with differentials resulting from cytocentrifugation, cells were isolated from 35 BALF samples using standard methods, and counted using a haematocytometer. Forty thousand cells in 200 microL were prepared by cytocentrifugation (3 min, 57 x g; Cytospin 2) and 5 x 10(5) cells in 5 microL by microscope slide smear. Both samples were air-dried, stained using May-Grünwald Giemsa stain, and 600 cells were counted to obtain differentials. To test the adequacy of sampling by the microscope slide smear technique, known quantities of lymphocytes or neutrophils were added to fixed numbers of BALF cells, microscope slide smears prepared, and differentials determined on 600 cells. The resulting differentials were compared to the calculated differentials. Preparation of BALF cells with the microscope slide smear technique yielded well-preserved cell morphology. Compared to cytocentrifugation, microscope slide smear preparations had significantly higher percentages of lymphocytes. The microscope slide smears for the samples with predetermined numbers of cells yielded lymphocyte and neutrophil percentages which did not differ from the calculated differentials (59.6 +/- 1.5 vs 59.6 +/- 5.2% and 54.6 +/- 6.0 vs 53.1 +/- 6.0%, respectively). Varying the number of cells counted from 100 to 800 confirmed the reproducibility of the counts for counting 600 cells. Using 5 x 10(5), 2.5 x 10(5), or 1 x 10(5) cells per preparation demonstrated that adequate specimens could be obtained from as few as 1 x 10(5) cells. Thus, microscope slide smear preparation is a simple and accurate method for the quantitation of bronchoalveolar lavage fluid cytology.
منابع مشابه
Pulmonary alveolar proteinosis: diagnosis using routinely processed smears of bronchoalveolar lavage fluid.
AIMS For the diagnosis of pulmonary alveolar proteinosis from bronchoalveolar lavage specimens it is normally necessary to make an ultrastructural examination. However, this is thought to be impractical for bronchoalveolar lavage specimens that have been routinely fixed in ethanol. In the present study, bronchoalveolar lavage cytology smears on slide glasses were examined directly ultrastructur...
متن کاملThe effects of Eucheuma cottonii on alveolar macrophages and malondialdehyde levels in bronchoalveolar lavage fluid in chronically particulate matter 10 coal dust-exposed rats
Objective(s):To investigate the effect of Eucheuma cottonii on alveolar macrophages (AM) and malondialdehyde (MDA) levels in bronchoalveolar lavage fluids (BALF) in particulate matter 10 (PM10) coal dust-exposed rats. Materials and Methods: Ten groups, including a non exposed group and groups exposed to coal dust at doses of 6.25 (CD6.25), 12.5 (CD12.5), or 25 mg/m3 (CD25) an hour daily for 6 ...
متن کاملBronchoalveolar Lavage Results Are Independent of Season, Age, Gender and Collection Site
BACKGROUND Clinical interpretation of bronchoalveolar lavage fluid results is dependent on the availability of reference values for healthy individuals. Only a few studies have published such reference values and the applicability of results is restricted by small sample sizes and the limited representativeness of the study population. We aim to investigate the influence of age, gender, collect...
متن کاملT-lymphocytosis in bronchoalveolar lavage fluid of hypersensitivity pneumonitis. Changes in profile of T-cell subsets during the course of disease.
Recently, increased proportions of OKT 4+ helper T-lymphocytes have been reported in bronchoalveolar lavage (BAL) fluid of patients with active sarcoidosis. In this study we were interested in T-cell subsets of hypersensitivity pneumonitis, a disease characterized by a similar increase in BAL T-lymphocytes as active sarcoidosis. We applied an immunoperoxidase method performed on glass slides us...
متن کاملUse of poly-l-lysine-coated slides in clinical bronchoalveolar lavage fluid samples.
OBJECTIVE Polylysine coating of microscope slides provides superior cell adhesion. We compared poly-l-lysine-coated (PLC) slides to conventional slides in cytocentrifuged bronchoalveolar lavage (BAL) fluid samples. STUDY DESIGN Twenty BAL fluid samples with representative numbers of alveolar macrophages, lymphocytes and polymorphonuclear neutrophils were cytocentrifuged on uncoated slides and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 9 3 شماره
صفحات -
تاریخ انتشار 1996