Temperature variation on root surface with three root-end cavity preparation techniques.

نویسندگان

  • Emre Bodrumlu
  • Ilker Keskiner
  • Mahmut Sumer
  • Nazife T Telcioglu
چکیده

INTRODUCTION Thermal changes can occur on the external root surface when root-end cavity preparation is performed, which may damage periodontal ligament cells and alveolar bone. OBJECTIVE The purpose of this study was to evaluate the temperature changes during preparation of the root-end cavities at 1 and 3 mm to the sectioned apical root surfaces when either tungsten carbide round bur, diamond round bur or ultrasonic diamond tip was used. METHODS Root-end resection was performed at 90 degrees to the long axis of the root, 3 mm from the apex. Specimens were randomly divided into three groups of 12 teeth each for three different root-end cavity preparation techniques to be used, i.e. tungsten carbide bur, diamond bur and ultrasonic diamond retro tip.Thermocouples were used to measure temperature changes at 1 mm (T1) and 3 mm (T2) to the cutting plane during the preparations. RESULTS For T1, the lowest and the highest mean temperature increases of 3.53 degrees C and 4.34 degrees C were recorded for the carbide and diamond burs, respectively. For T2, the lowest and the highest mean temperature increases of 2.62 degrees C and 4.39 degrees C where recorded for the carbide and diamond burs, respectively. The mean temperatures with the ultrasonic tip were 3.68 and 3.04 degrees C at T1 and T2 region, respectively. For root-end preparation, the ultrasonic preparation technique took the shortest preparation time (10.25 sec) and the diamond bur took the longest time (28.17 sec). CONCLUSION Ultrasonic retro tips and burs caused temperature to rise from 2.62 degrees to 4.39 degrees C, and these rises were within safety levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Investigation of Marginal Adaptation and Surface Defects of MTA and Root MTA as Two Root End Filling Materials

Introduction: This study was carried out to compare two retrograde filling materials entitled mineral trioxide aggregate (MTA) and Root MTA (RMTA) in regard to their marginal adaptation and surface defects. Method: In this study twenty extracted human teeth were used. In all teeth after cleaning and shaping, the root canals were obturated by gutta-percha and root canal sealer. After that in eac...

متن کامل

مقایسه و بررسی ایجاد ترک ها در تهیه حفره انتهای ریشه با استفاده از وسایل اولتراسونیک

One of the major goals of periradicular surgery is to create a good apical sea! at the apex. This is done by sectioning of 2 to 3mm from the apex, preparation of a class I cavity and filling with a biocompatible material.The purpose of this in vitro study was to determine whether ultrasonic units used for root end preparations could change the surface & structure of resected root ends, as compe...

متن کامل

Effectiveness of Er:YAG laser in cavity preparation for retrograde filling--in vitro study.

The purpose of this study was to determine the sealing quality of Super EBA cement in laser prepared root-end cavities in comparison with root-end cavities classically prepared with steel burrs. Two groups of three millimeter root sections were prepared. The first group was prepared with the Er:YAG laser and the second group with a steel burr mounted on a surgical handpiece. The sections were f...

متن کامل

Confocal microscopy: A valid approach to evaluate the three-dimensional characteristics of root-end cavities

OBJECTIVE To analyze, using confocal microscope, the three-dimensional characteristics of the root-end cavity preparations completed in root apices of extracted teeth determining their area, perimeter, circularity and cavo-surface angle. STUDY DESIGN Thirty-two single-rooted extracted teeth underwent endodontic treatment and apical resection. Root-end cavities were prepared according to 4 pro...

متن کامل

Scanning electron microscopic analysis of the integrity of the root-end surface after root-end management using a piezoelectric device: a cadaveric study.

INTRODUCTION The introduction of piezoelectric instruments in endodontic surgery allowed clinicians to manage the bone tissue with precision reducing the risk of damaging soft tissues. Although such instruments can also be used to prepare root-end cavity, few information is available on the effect of piezosurgery on dentine. This cadaveric study investigated the integrity of root apices after r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Srpski arhiv za celokupno lekarstvo

دوره 141 9-10  شماره 

صفحات  -

تاریخ انتشار 2013