Microelectrode recording duration and spatial density constraints for automatic targeting of the subthalamic nucleus.

نویسندگان

  • Reuben R Shamir
  • Adam Zaidel
  • Leo Joskowicz
  • Hagai Bergman
  • Zvi Israel
چکیده

BACKGROUND Accurate detection of the boundaries of the subthalamic nucleus (STN) in deep brain stimulation (DBS) surgery using microelectrode recording (MER) is considered to refine localization and may therefore improve clinical outcome. However, MER tends to extend operation time and its cost-utility balance has been debated. OBJECTIVES To quantify the tradeoff between accuracy of STN localization and the spatial and temporal parameters of MER that effect the operation time using an automated detection method. METHODS We retrospectively estimated the accuracy of STN detection on data from 100 microelectrode trajectories. Our dense (average step = 0.12 mm) and long (average duration = 22.5 s) MER data was downsampled in the spatial and temporal domains. Then, the STN borders were detected automatically on both the downsampled and original data and compared to each other. RESULTS With a recording duration of 16 s, average accuracy for detecting STN entry ranged from 0.06 mm for a 0.1-mm step to 0.51 mm for a 1.0-mm step. Smaller effects were found along the temporal axis. For example, a 0.1-mm recording step yielded an STN entry average accuracy ranging from 0.06 mm for a 16-second recording duration to 0.16 mm for 0.1 s. CONCLUSIONS STN entry detection error was about half of the step size. Sampling duration of STN activity can be minimized to 1 s/record without compromising accuracy. We conclude that bilateral DBS surgery time utilizing MER may be significantly shortened without compromising targeting accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A cost analysis of intraoperative microelectrode recording during subthalamic stimulation for Parkinson's disease.

Deep brain stimulation of the subthalamic nucleus is the standard of care for treating medically intractable Parkinson's disease. Although the adjunct of microelectrode recording improves the targeting accuracy of subthalamic nucleus deep brain stimulation in comparison with image guidance alone, there has been no investigation of the financial cost of intraoperative microelectrode recording. T...

متن کامل

Anatomical situation of the subthalamic nucleus (STN) from midcommissural point (MCP) in Parkinson\'s disease patients underwent deep brain stimulation (DBS): an MRI targeting study

  Abstract   Introduction: It is demonstrated that the degree of clinical improvement in   Parkinson's disease (PD) achieved by deep brain stimulation (DBS) is largely dependent   on the accuracy of lead placement. In addition, individual variability in the   situation of subthalamic nucleus (STN) is responsible for spatial inter-individual   fluctuations of the real patient's target.   Objecti...

متن کامل

Automatic analysis and visualization of microelectrode recording trajectories to the subthalamic nucleus: preliminary results.

Although microelectrode recordings (MER) are commonly used to confirm stereotactic targets during surgery for movement disorders, there is no consensus on whether the additional risks and cost of MER are worth the benefits. This may be due, in part, to the inconsistency and inefficiency of subjective interpretation of MER data that is currently used in practice. We describe several fully automa...

متن کامل

Is there still need for microelectrode recording now the subthalamic nucleus can be well visualized with high field and ultrahigh MR imaging?

Citation: Kocabicak E, Alptekin O, Ackermans L, Kubben P, Kuijf M, Kurt E, Esselink R and Temel Y (2015) Is there still need for microelectrode recording now the subthalamic nucleus can be well visualized with high field and ultrahigh MR imaging? Front. Integr. Neurosci. 9:46. doi: 10.3389/fnint.2015.00046 Is there still need for microelectrode recording now the subthalamic nucleus can be well ...

متن کامل

Final Electrode Position in Subthalamic Nucleus Deep Brain Stimulation Surgery: A Comparison of Indirect and Direct Targeting Methods.

AIM High frequency stimulation of the subthalamic nucleus (STN) is nowadays a widely performed surgery for patients with Parkinson's disease (PD). The field has witnessed a shift from indirect targeting to direct targeting. The question arises whether this change has influenced the final electrode position in STN deep brain stimulation surgery. To address this question, we compared the final el...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stereotactic and functional neurosurgery

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 2012