High Power CW Wattmeter Calibration at NIST
نویسندگان
چکیده
The National Institute of Standards and Technology has established a measurement capability to support high power systems and devices. The automated wattmeter calibration system operates at power levels of 1 to 1000 W for frequencies from 1 to 30 MHz and 1 to 500 W from 30 to 400 MHz. A cascaded coupler technique is used to extend power measurements to high levels which are traccable to a 10 mW standard thermistor mount. This technique uses an arrangement of nominal 10, 20, 30, 40, and 50 dB couplers with sidearm power meters. The initial step transfers the calibration of the 10 mW standard to the 10 dB coupler/power meter. The standard is then replaced with a wattmeter to be calibrated. RF power is increased 10 dB and the calibration is transferred to the adjacent 20 dB eoupler/power meter. This sequence is repeated with the remaining coupler/power meters until the wattmeter is calibrated at the desired power levels and frequencies. Power ratios calculated from simultaneous power measurements made at each transfer are used to calculate the incident power at the wattmeter. Due to nonideal components, corrections are made for nonlinearities, mismatch, and other errors. Two types of wattmeters have been evaluated at selected frequencies and power levels. Total uncertainties are based on the random and systematic components.
منابع مشابه
Reflective Optical Chopper Used in NIST High-Power Laser Measurements
For the past ten years, NIST has used high-reflectivity, optical choppers as beamsplitters and attenuators when calibrating the absolute responsivity and response linearity of detectors used with high-power CW lasers. The chopper-based technique has several advantages over the use of wedge-shaped transparent materials (usually crystals) often used as beam splitters in this type of measurement s...
متن کاملLong-Term Stability of the NIST Standard Ultrasonic Source
The National Institute of Standards and Technology (NIST) Standard Ultrasonic Source (SUS) is a system comprising a transducer capable of output power levels up to 1 W at multiple frequencies between 1 MHz and 30 MHz, and an electrical impedance-matching network that allows the system to be driven by a conventional 50 Ω rf (radio-frequency) source. It is designed to allow interlaboratory replic...
متن کاملDsp Based Power Analyzing System for Onsite Measurements
− A three-phase power analyzing system based on digital signal processing (DSP) has been developed as a traveling standard for onsite power calibration. The design and operation is described for a sampling wattmeter capable of measuring power parameters of sinusoidal signal with frequencies of 50 to 60 Hz and measuring harmonics of nonsinusoidal signals up to 3 kHz. The system is utilized with ...
متن کاملNonlinearity Measurements of High-Power Laser Detectors at NIST
We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST...
متن کاملLow-Background Temperature Calibration of Infrared Blackbodies
The stability of blackbody sources and their ability to be modeled accurately make them well suited for radiometric calibration activity. However, the implementation of the blackbody in industry or the laboratory may, and often does result in blackbody performance that deviates from ideal. The Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology (NIST) w...