Effect of packing types on the dimensional accuracy of denture base resin cured by the conventional cycle in relation to post-pressing times.

نویسندگان

  • Rafael Leonardo Xediek Consani
  • Saide Sarckis Domitti
  • Marcelo Ferraz Mesquita
  • Simonides Consani
چکیده

This study investigated the dimensional stability of denture bases influenced by packing methods, in relation to post-pressing times, in the Clássico acrylic resin which was prepared according to manufacturer recommendations. Forty maxillary wax bases were made and randomly assigned into 2 groups of 20 specimens each according to the conventional and RS system packing methods. In each method, the specimens were subdivided into immediate, 6, 12 and 24 h post-pressing times. The dough of the acrylic resin was packed in metallic flasks and processed in a water bath curing cycle at 74 masculine C for 9 h. After cooling at room temperature, the bases were removed from the flasks, finished and fixed on stone casts with instantaneous adhesive. The resin base-stone cast sets were transversally sectioned into 3 sections and the base-stone gap measured at 5 points in each section. The data were submitted to ANOVA and Tukey's test, which showed that the RS system had a smaller base distortion compared to conventional packing, with the exception of the 24-h post-pressing time. There was a statistically significant difference between the packing methods only in section C (posterior palatal zone). In the conventional packing method, the immediate and 6 h times demonstrated values with no statistically significant difference between them, as well as between the 12 and 24 h post-pressing times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of the Flexural Strength of Heat Polymerized Acrylic Resin with the Addition of 8% and 13% Aluminum Oxide Powder: An In-vitro Study

Introduction: Acrylic resins have been used successfully as denture bases. However, acrylic resin denture base materials are brittle and have poor strength and thermal conductivity. Therefore, it is essential to improve the flexural strength of heat polymerized acrylic resin. The present study aimed to evaluate and compare the flexural strength of heated polymerized acrylic res...

متن کامل

Effect of Flask Types, Post-pressing Times and Base Regions on the Adaptation of Complete Dentures

This study aimed to evaluate the effect of flask types, post-pressing times and base regions on the base adaptation of maxillary and mandibular complete dentures. Denture bases were waxed in stone casts and randomly divided into six groups (n=10), according to conventional and double flasks inclusion, and immediate and 6 hours post-pressing times. Denture bases were polymerized in water bath at...

متن کامل

Does Addition of Silver Nanoparticles to Denture Base Resin Increase Its Thermal Conductivity?

  Objective: Studies have demonstrates that physical properties of denture base affect patient satisfaction and acceptance. Thermal conductivity is among the most important properties of denture base influencing the sense of taste and gingival health. The conventionally used acrylic resin has a low coefficient of thermal conductivity. This study aimed to improve the thermal conductivity of acry...

متن کامل

Effect of Stone Cast Type on Complete Denture Base Adaptation

Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...

متن کامل

A comparative evaluation of the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle: an in vitro study.

AIM The aim of this study is to evaluate the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle. MATERIALS AND METHODS In this study, a total of 60 standardized maxillary record bases were fabricated with seven reference points as follows: Point A: Incisive papilla, Point B and C: Can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2004