Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system.

نویسندگان

  • P Alaei
  • B J Gerbi
  • R A Geise
چکیده

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning system designed for use in the megavoltage energy range can be used for calculating organ doses in the diagnostic energy range. Our doses compare well with those previously reported. Differences are partly due to variations in experimental techniques. Using a three-dimensional (3-D) treatment planning system to calculate dose also allows us to generate dose volume histograms (DVH) and compute normal tissue complication probabilities (NTCP) for diagnostic procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

متن کامل

Dose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom

Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS).  In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plans.

PURPOSE Cone beam CT is increasingly being used for daily patient positioning verification during radiation therapy treatments. The daily use of CBCT could lead to accumulated patient doses higher than the older technique of weekly portal imaging. There have been several studies focusing on measurement or calculation of the patient dose from CBCT recently. METHODS This study investigates the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2001