Lateral flow immunochromatographic assay for sensitive pesticide detection by using Fe3O4 nanoparticle aggregates as color reagents.
نویسندگان
چکیده
Magnetic Fe(3)O(4) particle aggregates were prepared by cross-linking Fe(3)O(4) nanoparticles bearing surface carbonyl groups with poly-L-lysine. Upon further coupling with antiparaoxon methyl polyclonal antibody, the resultant particle aggregate-based probes were used in a lateral flow immunochromatographic assay (LFIA) of pesticide residue of paraoxon methyl. The results were compared with that achieved by using the mother Fe(3)O(4) nanoparticles. More quantitative results on the signal amplification effect endowed by the controlled aggregation of Fe(3)O(4) nanoparticles were extracted by relative optical density analysis. Under optimized conditions, a detection limit of 1.7 ng/mL for paraoxon methyl was achieved by using the particle aggregates, which is almost 40-fold lower than that based on the mother Fe(3)O(4) nanoparticles.
منابع مشابه
Lateral flow immunoassay with the signal enhanced by gold nanoparticle aggregates based on polyamidoamine dendrimer.
In order to amplify the signal in a gold nanoparticle-based lateral flow immunoassay, a simple and sensitive method utilizing gold nanoparticle aggregates as a colored reagent formed with a polyamidoamine dendrimer was developed. The results were compared with that achieved by employing the individual nanoparticles used in the conventional lateral flow immunoassay. Under the optimized experimen...
متن کاملFe3O4 magnetic nanoparticle peroxidase mimetic-based colorimetric assay for the rapid detection of organophosphorus pesticide and nerve agent.
Rapid and sensitive detection methods are in urgent demand for the screening of extensively used organophosphorus pesticides and highly toxic nerve agents for their neurotoxicity. In this study, we developed a novel Fe(3)O(4) magnetic nanoparticle (MNP) peroxidase mimetic-based colorimetric method for the rapid detection of organophosphorus pesticides and nerve agents. The detection assay is co...
متن کاملReagentless bidirectional lateral flow bioactive paper sensors for detection of pesticides in beverage and food samples.
A reagentless bioactive paper-based solid-phase biosensor was developed for detection of acetylcholinesterase (AChE) inhibitors, including organophosphate pesticides. The assay strip is composed of a paper support (1 x 10 cm), onto which AChE and a chromogenic substrate, indophenyl acetate (IPA), were entrapped using biocompatible sol-gel derived silica inks in two different zones (e.g., sensin...
متن کاملDevelopment of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملGold-Nanoparticle-Decorated Silica Nanorods for Sensitive Visual Detection of Proteins
We report a rapid and highly sensitive approach based on gold-nanoparticle-decorated silica nanorods (GNP-SiNRs) label and lateral-flow strip biosensor (LFSB) for visually detecting proteins. Owing to its biocompatibility and convenient surface modification, SiNRs were used as carriers to load numerous GNPs, and the GNP-SiNRs were used as labels for the lateral-flow assay. The LFSB detection li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 83 17 شماره
صفحات -
تاریخ انتشار 2011