The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mapping

نویسندگان

  • Bengt Johansson
  • Sonya V Babu-Narayan
  • Philip J Kilner
چکیده

BACKGROUND Pulmonary regurgitation is a common and clinically important residual lesion after repair of tetralogy of Fallot. Cardiovascular magnetic resonance (CMR) phase contrast velocity mapping is widely used for measurement of pulmonary regurgitant fraction. Breath-hold acquisitions, usually acquired during held expiration, are more convenient than the non-breath-hold approach, but we hypothesized that breath-holding might affect the amount of pulmonary regurgitation. METHODS Forty-three adult patients with a previous repair of tetralogy of Fallot and residual pulmonary regurgitation were investigated with CMR. In each, pulmonary regurgitant fraction was measured from velocity maps transecting the pulmonary trunk, acquired during held expiration, held inspiration, by non-breath-hold acquisition, and also from the difference of right and left ventricular stroke volume measurements. RESULTS Pulmonary regurgitant fraction was lower when measured by velocity mapping in held expiration compared with held inspiration, non-breath-hold or stroke volume difference (30.8 vs. 37.0, 35.6, 35.4%, p = 0.00017, 0.0035, 0.026). The regurgitant volume was lower in held expiration than in held inspiration (41.9 vs. 48.3, p = 0.0018). Pulmonary forward flow volume was larger during held expiration than during non-breath-hold (132 vs. 124 ml, p = 0.0024). CONCLUSION Pulmonary regurgitant fraction was significantly lower in held expiration compared with held inspiration, free breathing and stroke volume difference. Altered airway pressure could be a contributory factor. This information is relevant if breath-hold acquisition is to be substituted for non-breath-hold in the investigation of patients with a view to re-intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow measurement by magnetic resonance: a unique asset worth optimising.

Users and manufacturers of cardiovascular magnetic resonance (CMR) systems have, potentially, an unrivalled asset. Phase contrast mapping of velocities through planes transecting the great arteries should provide the most accurate measurements available of cardiac output, shunt flow, aortic or pulmonary regurgitation and, indirectly, of mitral regurgitation. But the reality is that phase contra...

متن کامل

Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping.

BACKGROUND Pulmonary regurgitation frequently occurs after surgical correction of tetralogy of Fallot. To date, reliable quantitation of pulmonary regurgitation has not been possible, and therefore the clinical significance of pulmonary regurgitation is controversial. Nuclear magnetic resonance (NMR) velocity mapping allows accurate measurement of volumetric flow. The feasibility and accuracy o...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Effect of systemic sclerosis on left ventricular long-axis motion and left ventricular mass assessed by magnetic resonance.

The aim of this study was to assess the effect of scleroderma on left ventricular mass and subendocardial function using cardiovascular magnetic resonance (CMR) to determine parameters reflecting early dysfunction from fibrosis. Fifteen patients with a history of scleroderma had left ventricular mass measured with standard techniques and regional subendocardial contractile function assessed usi...

متن کامل

Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements.

Evaluating the in vivo accuracy of magnetic resonance phase velocity mapping (PVM) is not straightforward because of the absence of a validated clinical flow quantification technique. The aim of this study was to evaluate PVM by investigating its precision, both in vitro and in vivo, in a 1.5 Tesla scanner. In the former case, steady and pulsatile flow experiments were conducted using an aortic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiovascular Magnetic Resonance

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009