Full and hybrid 2-dimensional navigator echo correction: new techniques to suppress respiratory-induced physiological noise in echo-planar functional MRI
نویسندگان
چکیده
R. L. Barry, R. S. Menon Centre for Functional and Metabolic Mapping, Robarts Research Institute, London, Ontario, Canada, Departmant of Biomedical Engineering, University of Western Ontario, London, Ontario, Canada, Department of Diagnostic Radiology and Nuclear Medicine, University of Western Ontario, London, Ontario, Canada Introduction The spatio-temporal variation of magnetic field inhomogeneities in the brain due to normal subject respiration is a troublesome problem in fMRI, and particularly so at higher fields where sources of physiological noise can nullify potential gains that one may expect from increases in signal-to-noise ratio and blood oxygenation leveldependent (BOLD) contrast-to-noise ratio (CNR) [1]. An assumption held since 1994 is that field inhomogeneities induced by respiration are approximately uniform in an axial slice, and thus a global measurement and correction would be appropriate [2]. However, recent magnetic field measurements using RASTAMAP [3] show clear spatial variations in the field inhomogeneities between full inhalation and exhalation, suggesting that current correction strategies may not be adequate. Global and 1-dimensional (1D) navigator echo corrections applied to simulated fMRI data acquired using a 2-shot echo-planar imaging (EPI) sequence under the influence of the measured respiratory-induced frequency offset map (FOM) demonstrated both reductions and amplifications of this noise throughout an axial image [4]. Therefore, our goal was to develop a new 2-dimensional (2D) navigator echo correction technique to improve the suppression of respiratory-induced physiological noise in fMRI. Methods Experiments were performed on a Varian Unity INOVA whole-body 4 Tesla MRI scanner (Palo Alto, CA) with a Siemens Sonata gradient coil (Erlangen, Germany), and simulations were implemented using custom software written in MATLAB 7.0 (MathWorks, Natick, MA). Global and 1D navigator echo corrections are implemented as previously described [2,4]. A 2-shot 64 x 64 EPI sequence is simulated (TE = 22 ms, TR = 525 ms) to investigate the peak-to-peak respiratory-induced intensity fluctuation within an axial slice of a typical whole-brain fMRI experiment. In these experiments, the less-preferred gradient orientation is chosen (read in left-right direction and phase encode in anterior-posterior direction) [4] to investigate the performance of 2D navigator echo correction over either global or 1D correction using this gradient configuration. Full 2D Correction Step 1: By monitoring the phase of the center of k-space, select a complex reference image Iref with minimal phase offsets from functional images collected at the beginning of each functional run. Step 2a: As the FOM is modulated by the respiration cycle, separate estimates of ∆B must be made for kspace data acquired after each radiofrequency (RF) pulse. Estimate ∆Btop = {φ(Icur) – φ(Iref)} / TE for each image, where Icur and Iref are formed using the inverse Fourier transform of only the top halves of k-space. Step 2b: Repeat Step 2a to estimate ∆Bbot using only the bottom halves of k-space. Step 3: Construct two complex N x N matrices G and D. G is the ideal encoding matrix where each row contains only the phase map in image space due to the gradients, and D is the distorted encoding matrix where each row contains the phase map due to both the gradients and the field inhomogeneities ∆B. Step 4: If kacq is the acquired k-space data (an N 2 x 1 vector), then kacq = Dm, where m is the desired image. The corrected image is then k2Dcor = Gm = (GD )kacq where D –1 is calculated by direct matrix inversion. Hybrid 2D Correction (Steps 1, 2a, and 2b are the same as above.) Step 3: Define a δ x δ square region in the center of k-space (1 ≤ δ ≤ N). Construct G and D as above, but they now have dimensions of δ x N. D is now the N x δ pseudo-inverse of D. Step 4: kcenter is a δ x 1 vector consisting of the data acquired in the center of k-space. The 2D corrections are applied to these data and kcenter,2Dcor = (GD )kcenter . Step 5: Apply a global navigator echo correction to the remaining (N – δ) periphery points of k-space. Results Figure 1 displays the evolution of the intensity for a representative single pixel region of interest (ROI) in gray matter. Intensity changes are due solely to the presence of the respiratory-induced FOM model [4]. The peak-to-peak signal intensity fluctuation is 2.22% with no phase correction, and decreases to almost identical values of 0.759% and 0.752%, respectively, for global and 1D corrections. This fluctuation is further decreased to 0.199% with full 2D correction, clearly demonstrating the usefulness of a robust 2D navigator echo correction technique in reducing this source of physiological noise by a full order of magnitude. Discussion Full 2D navigator echo correction may be considered the “gold standard” in suppressing respiratoryinduced physiological noise in multi-shot EPI; however, it comes at a significant cost of both memory and computation time. A priori knowledge that these induced magnetic field inhomogeneities vary slowly in space [4] suggests that phase distortions will manifest themselves primarily in the low-frequency region of kspace. Rigorous 2D phase corrections should therefore be most beneficial when applied to the central δ x δ square region of k-space. Thus, the proposed partial 2D / global (i.e., hybrid) correction technique is a compromise between correction accuracy and execution time. Figure 2 shows the expected value of peak-topeak noise fluctuations for δ = 1, 2, 4, 16, and 32 in a large ROI consisting of several hundred gray matter pixels. When δ > 4, this noise level is decreased beyond the levels achieved using global and 1D corrections. Furthermore, when δ ≥ 16, the noise fluctuations are reduced to a level comparable to what is achievable using full 2D correction. Whereas full 2D correction may require several minutes to process each 64 x 64 image, hybrid 2D correction with δ = 16 requires only a few seconds per image, making it feasible to apply this technique to typical fMRI data sets that consist of thousands of individual 2D images. Future work will investigate extensions of this hybrid 2D navigator echo correction technique so that it may be used in the retrospective suppression of physiological noise in high-resolution fMRI studies utilizing 4 or 8-shot EPI sequences. References [1] Kruger G, Glover GH. Physiological noise in oxygenation-sensitive magnetic resonance imaging. MRM 2001;46:631-637. [2] Hu X, Kim S-G. Reduction of signal fluctuation in functional MRI using navigator echoes. MRM 1994;31:495-503. [3] Klassen LM, Menon RS. Robust automated shimming technique using arbitrary mapping acquisition parameters (RASTAMAP). MRM 2004;51:881-887. [4] Barry RL, Menon RS. Modeling and suppression of respiration-related physiological noise in echo-planar functional magnetic resonance imaging using global and one-dimensional navigator echo correction. MRM 2005;54:411-418. Figure 2: Mean percentage noise fluctuation within the gray matter ROI (acquired using a 2shot EPI sequence) with hybrid 2D navigator echo correction for δ = 1, 2, 4, 8, 16, and 32. The mean noise fluctuation with no correction, global correction, 1D correction, and full 2D correction are shown for comparison. When δ = 16, the performance of hybrid 2D correction is virtually identical to full 2D correction. Figure 1: Normalized peak-to-peak pixel intensity fluctuation for an ROI with no navigator echo correction (2.22%), global correction (0.759%), 1D correction (0.752%), and full 2D correction (0.199%). Full 2D correction reduced this noise by an additional 0.55% beyond global or 1D correction.
منابع مشابه
Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging.
In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "...
متن کاملHigh-Resolution Functional MRI at 3 T: 3D/2D Echo-Planar Imaging with Optimized Physiological Noise Correction
High-resolution functional MRI (fMRI) offers unique possibilities for studying human functional neuroanatomy. Although high-resolution fMRI has proven its potential at 7 T, most fMRI studies are still performed at rather low spatial resolution at 3 T. We optimized and compared single-shot two-dimensional echo-planar imaging (EPI) and multishot three-dimensional EPI high-resolution fMRI protocol...
متن کاملHigh-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition
High-resolution diffusion MRI can provide the ability to resolve small brain structures, enabling investigations of detailed white matter architecture. A major challenge for in vivo high-resolution diffusion MRI is the low signal-to-noise ratio. In this work, we combine two highly compatible methods, ultra-high field and three-dimensional multi-slab acquisition to improve the SNR of high-resolu...
متن کاملNavigator-Free Dynamic Phase Correction for Echo-Planar Imaging Based Functional MRI
INTRODUCTION In dynamic echo-planar imaging (EPI), such as functional MRI, where a time series of EPI images are collected, there is additional modulation along echo readout due to changes in hardware states (e.g., temperature) that the standard reference scan based phase correction methods [1-3] cannot account for, thereby resulting in an increase of ghost level over time. To address this prob...
متن کاملWhole-Heart Coronary MRA
Background MRI was first reported to visualize the ostia of the coronary arteries in the late 1980’s (1, 2). Tremendous progress has been made in coronary MRA ever since. One of the milestones was the acquisition of k-space data in a segmented mode (3, 4), allowing collection of an entire data set within multiple heartbeats. Early coronary MRA studies used two-dimensional (2D) technique to acqu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005