Controllers For A VSC-HVDC Link Connected To A Weak AC System

نویسندگان

  • R. S. Geetha
  • Ravishankar Deekshit
چکیده

In this paper, the interconnection of a strong AC system to a weak AC system by using a Voltage Source Converter (VSC) based High Voltage DC (HVDC) transmission system is investigated. In this work, the weak AC system considered is an island system comprised of synchronous generators and passive load. Analysis is carried out for UPF load and inductive load. The ac filter requirement to achieve the required response for UPF and inductive load is carried out. For efficient functioning of the system considered, proper designing of the controllers is an important factor. The controller parameters are designed using Modulus Optimum technique and Symmetric optimum method. The performance analysis of VSC-HVDC is carried out for power transmission in the DC link for load variation in the island system. Simulations are carried out in MATLAB/ Simulink / Sim Power Systems and the results are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Control and Transient Analysis of Voltage Source Converter Based Multi Terminal Dc System

As one of the key technologies of large scale access of distributed energy resources, the HVDC transmission system has great potential for further development. Therefore, in the past decades, the problem associated with HVDC converters connected to weak AC networks has become an important research field. The one of particular interest, and highest in consequences, is the AC voltage stability at...

متن کامل

Fault Ride-through Capability Enhancement of Voltage Source Converter-High Voltage Direct Current Systems with Bridge Type Fault Current Limiters

This paper proposes the use of bridge type fault current limiters (BFCLs) as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC) systems. Since VSC-HVDC systems are vulnerable to faults, it is essential to enhance the fault ride-through (FRT) capability with auxiliary control devices like BFCLs. BFCL controllers have been d...

متن کامل

Paper title: VSC-HVDC Control and Application in Meshed AC Networks

VSC-HVDC is a fully controllable transmission device, allowing rapid and independent control of active power transmitted over the dc link and reactive power at each end of the dc link. Embedding VSC-HVDC in meshed ac networks opens up new possibilities to improve power grid reliability and efficiency. The general control architecture of VSC-HVDC system is presented with focus on converter contr...

متن کامل

Simulation Study of Dynamic Fault Recovery Performance of VSC-HVDC System

The fault recovery of VSC-HVDC transmission system is often influenced by many factors, such as the reactive power compensation characteristics of the inverter and the dynamic performance of DC controllers. In this paper, the PSCAD/ EMTDC simulation tool is used to study the dynamic recovery performance of VSC-HVDC system for several different var compensating devices in VSC-HVDC inverter-Fixed...

متن کامل

Investigation of Hybrid Pseudo Bipolar HVDC Performances Supply Power to Passive AC Network

The traditional HVDC plays an important role in the development of power grid. But the traditional HVDC cannot supply power either to entirely passive AC network or to weak AC system. In fact, an entirely passive AC network can be effectively powered through VSC-HVDC. However, the cost of investment in VSC-HVDC is amazingly high due to the limitation of power electronics technology. Based on CS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015