Does a monochromator improve the precision in quantitative HRTEM?

نویسندگان

  • A J den Dekker
  • S Van Aert
  • D Van Dyck
  • A van den Bos
  • P Geuens
چکیده

This paper addresses the question as to what extent the incorporation of a monochromator in an electron microscope can enhance the performance of high resolution transmission electron microscopy (HRTEM). The monochromator will reduce the chromatic aberration, and hence the information limit, at the expense of beam current, leading to a decrease in signal intensity and a corresponding decrease in signal-to-noise ratio (SNR). Both aspects, information limit and SNR, have been included in a quantitative evaluation based on the statistical precision with which the position of an atom column can be estimated. It is shown that the effect of a monochromator on the attainable precision depends on the microscope and monochromator parameters, as well as on the characteristics of the object.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum HRTEM image contrast at 20 kV and 80 kV--exemplified by graphene.

The dependence of high-resolution transmission electron microscopy (HRTEM) image contrast of graphene on the adjustable parameters of an aberration-corrected microscope operated at 80 and 20 kV has been calculated and, for 80 kV, compared with measurements. We used density functional theory to determine the projected atom potential and obtained the image intensity by averaging over the energy d...

متن کامل

A Comparative Study on Instrumental Precision of Refrigerated and Non-Refrigerated Auto-Analyzers in Order to Improve Quality Assurance in Biochemistry Laboratory

Background and Objective: Quality control is one of the most important components in order to improve quality assurance in laboratories during analytical steps. For this purpose, coefficient of variation plays an important role. Due to the fast improvement in technology, application of inferential statistics for the comparisons ...

متن کامل

Overdiagnosis: An Important Issue That Demands Rigour and Precision; Comment on “Medicalisation and Overdiagnosis: What Society Does to Medicine”

Van Dijk and colleagues present three cases to illustrate and discuss the relationship between medicalisation and overdiagnosis. In this commentary, I consider each of the case studies in turn, and in doing so emphasise two main points. The first is that it is not possible to assess whether overdiagnosis is occurring based solely on incidence rates: it is necessary also to have data about the b...

متن کامل

Developing a Method for Increasing Accuracy and Precision in Measurement System Analysis: A Fuzzy Approach

Measurement systems analysis (MSA) has been applied in different aspect of industrial assessments to evaluate various types of quantitative and qualitative measures. Qualification of a measurement system depends on two important features: accuracy and precision. Since the capability of each quality system is severely related to the capability of its measurement system, the weakness of the two...

متن کامل

Upgrades to the XRD1 beamline optics and endstation at the LNLS

XRD1 was the first X-ray diffraction beamline to be built at the LNLS and after approximately 12 years of operation it was substantially updated to improve beam stability, increase the reliability of the monochromator movement as well as provide an experimental hutch that would meet the demands of users. The improvements included the construction of an independent concrete slab below the mirror...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 89 4  شماره 

صفحات  -

تاریخ انتشار 2001