Screw depth sounding in proximal humerus fractures to avoid iatrogenic intra-articular penetration.
نویسندگان
چکیده
Unstable and displaced proximal humerus fractures remain a treatment challenge. The use of locked plates has improved construct stability, but complication rates remain high. Biomechanical studies have emphasized the importance of anchoring screws in the subchondral bone of the humeral head to improve implant stability. However, the spherical shape of the proximal humerus and the limited tactile sensation of its soft cancellous bone make determining accurate screw length difficult, and reported rates of intraoperative screw penetration are high. Iatrogenic screw penetration, even if recognized and corrected before leaving the operating room, may lead to late failure. We present a simple technique of quickly and safely determining screw length using a blunt-tipped Kirschner wire and instruments found in basic orthopaedic sets.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملClinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the proper screw length through the depth gauge in elderly patients and compared the clinical effects wi...
متن کاملFluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of “Plate” and “Screw” Views
Proximal humeral fractures are common injuries with increasing incidence, particularly in the aging population. Nondisplaced or minimally displaced fractures can be treated conservatively whereas surgical fixation is usually indicated in the cases of displaced fractures. Various surgical options have been used for treatment of these fractures. Good outcomes have been reported with use of the Pr...
متن کاملDISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION
Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...
متن کامل[Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].
OBJECTIVES This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. PATIENTS AND METHODS Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 25 10 شماره
صفحات -
تاریخ انتشار 2011