Radiation-induced signals analysed by EPR spectrometry applied to fortuitous dosimetry.
نویسندگان
چکیده
Dosimetry based on the detection by electron paramagnetic resonance (EPR) spectroscopy of ionizing radiation-induced radicals is an established method for the retrospective dosimetry of past exposures and the dosimetry of potentially exposed persons in radiological emergencies. The dose is estimated by measuring the physical damage induced in materials contained in objects placed on or next to the potentially exposed person. The aim of this paper is to survey the current literature about methodologies and materials that have been proposed for EPR dosimetry, in order to identify those that could be suitable for population triage according to criteria such as ubiquity, non invasiveness and easy sample collection, presence of a post-irradiation EPR signal, negligible background signal, linearity of dose-response relationship, minimum detection limit and post-irradiation signal stability. The paper will survey the features of sugar, plastics, glass, clothing tissues, and solid biological tissues (nails, hair and calcified tissues).
منابع مشابه
ساخت دزیمتر EPR نانوبلور استرانسیوم سولفات آلاییده با دیسپرسیوم و بررسی خواص دزیمتری آن
The dosimetric characteristics of γ-radiation induced defects in strontium sulfate rod dosimeter were investigated using electron paramagnetic resonance (EPR) technique focusing on the dose range of 10–15000 Gy. The most significant EPR signals of spectroscopic splitting factor (g-value) g=2.0036 ، g=2.0090 and g=2.0160 were observed and attributed respectively to the SO4¯, SO3&...
متن کاملOverview of physical dosimetry methods for triage application integrated in the new European network RENEB.
PURPOSE In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Re...
متن کاملState of the art in nail dosimetry: free radicals identification and reaction mechanisms
Until very recently, analysis of bone biopsies by means of the method of electron paramagnetic resonance (EPR) collected after surgery or amputation has been considered as the sole reliable method for radiation dose assessment in hands and feet. EPR measurements in finger- and toenail have been considered for accident dosimetry for a long time. Human nails are very attractive biophysical materi...
متن کاملEPR and OSL emergency dosimetry with teeth: A direct comparison of two techniques
The OSL dosimetry technique with teeth has been validated against the EPR dosimetry technique through a measurement comparison performed on the same teeth. The OSL reconstructed doses were found to be in agreement with corresponding EPR doses. Minimum measurable doses for the OSL technique were estimated to be in the range 0.9e1.5 Gy for measurements made within 24 h post-exposure if OSL signal...
متن کاملEmergency EPR and OSL dosimetry with table vitamins and minerals.
Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated promine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2009