Retrospective evaluation of CTV to PTV margins using CyberKnife in patients with thoracic tumors

نویسندگان

  • Alejandro Floriano
  • Rafael García
  • Ramón Moreno
  • Alberto Sánchez‐Reyes
چکیده

The objectives of this study were to estimate global uncertainty for patients with thoracic tumors treated in our center using the CyberKnife VSI after placement of fiducial markers and to compare our findings with the standard CTV to PTV margins used to date. Datasets for 16 patients (54 fractions) treated with the CyberKnife and the Synchrony Respiratory Tracking System were analyzed retrospectively based on CT planning, tracking information, and movement data generated and saved in the logs files by the system. For each patient, we analyzed all the main uncertainty sources and assigned a value. We also calculated an expanded global uncertainty to ensure a robust estimation of global uncertainty and to enable us to determine the position of 95% of the CTV points with a 95% confidence level during treatment. Based on our estimation of global uncertainty and compared with our general mar- gin criterion (5 mm in all three directions: superior/inferior [SI], anterior/posterior [AP], and lateral [LAT]), 100% were adequately covered in the LAT direction, as were 94% and 94% in the SI and AP directions. We retrospectively analyzed the main sources of uncertainty in the CyberKnife process patient by patient. This individualized approach enabled us to estimate margins for patients with thoracic tumors treated in our unit and compare the results with our standard 5 mm margin. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The heterogeneous CTV-PTV margins should be given for different parts of tumors during tomotherapy

Objective The purpose of this study was to evaluate CTV-PTV margins of tumors for tomotherapy. Methods Setup errors were analyzed for 151 patients receiving helical tomotherapy treatment. 53 patients had head and neck tumors, 45 had thoracic tumors, 20 had abdominal tumors, and 33 had pelvic tumors. The setup errors were calculated in six directions, i.e. +X (left), -X (right), +Y (head), -Y ...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

A novel CBCT-based method for derivation of CTV-PTV margins for prostate and pelvic lymph nodes treated with stereotactic ablative radiotherapy

BACKGROUND Traditional CTV-PTV margin recipes are not generally applicable in the situation of stereotactic ablative radiotherapy (SABR) treatments of multiple target volumes with a single isocentre. In this work, we present a novel geometric method of margin derivation based on CBCT-derived anatomical data. METHODS Twenty patients with high-risk localized prostate cancer were selected for re...

متن کامل

Determination of optimal PTV margin for patients receiving CBCT‐guided prostate IMRT: comparative analysis based on CBCT dose calculation with four different margins

Variations in daily setup and rectum/bladder filling lead to uncertainties in the delivery of prostate IMRT. The purpose of this study is to determine the optimal PTV margin for CBCT-guided prostate IMRT based on daily CBCT dose calculations using four different margins. Five patients diagnosed with low-risk prostate cancer were treated with prostate IMRT to 70 Gy in 28 fractions using daily CB...

متن کامل

Accelerated Partial Breast Irradiation: Using the CyberKnife as the Radiation Delivery Platform in the Treatment of Early Breast Cancer

We evaluate the CyberKnife (Accuray Incorporated, Sunnyvale, CA, USA) for non-invasive delivery of accelerated partial breast irradiation (APBI) in early breast cancer patients. Between 6/2009 and 5/2011, nine patients were treated with CyberKnife APBI. Normal tissue constraints were imposed as outlined in the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology G...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014