A sensitive fluorescence optosensor for analysing propranolol in pharmaceutical preparations and a test for its control in urine in sport.

نویسندگان

  • J F Fernández-Sánchez
  • A Segura Carretero
  • C Cruces-Blanco
  • A Fernández-Gutiérrez
چکیده

We describe a simple and selective method for analysing propranolol and a sensitive test for its control in urine. A flow-through fluorescence optosensor based on on-line immobilization in a non-ionic-exchanger (Amberlite XAD-7) solid support in a continuous flow was used in both cases. Determination was made in 5 mM H(2)PO(4)(-)/HPO(4)(2-) buffer solution at pH 6 at a working temperature of 20 degrees C. Fluorescence intensities were measured at lambda(ex/em) = 300/338 nm with a response time of 80 s, thus obtaining a linear concentration range of between 0 and 250.0 ng ml(-1) with a detection limit of 1.3 ng ml(-1), an analytical sensitivity of 6.0 ng ml(-1) and a standard deviation of 2.40% at a 150 ng ml(-1) concentration level for propranolol. We also propose a test to detect propranolol in urine with a linear concentration range between 0 and 100.0 ng ml(-1), a detection limit of 0.2 ng ml(-1), an analytical sensitivity of 1.0 ng ml(-1), and a standard deviation of 0.84% at a 75 ng ml(-1) concentration level. The effect of proteins presents in urine samples were evaluated. The two proposed methods were satisfactorily applied to commercial formulations and urine samples respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Studies of Interaction between Propranolol and Human Serum Albumin in the Presence of DMMP by Molecular Spectroscopy and Molecular Dynamics Simulation

The interaction between propranolol (PROP) and human serum albumin (HSA) was studied in the presence of dimethyl methylphosphonate (DMMP). DMMP is usually considered as a simulant for chemical warfare agents (CWAs). For this purpose fluorescence quenching, resonance light scattering (RLS), synchronous, three-dimensional fluorescence spectroscopy and molecular dynamics (MD) simulation were emplo...

متن کامل

A rapid and sensitive HPLC-Fluorescence method for determination of Mirtazapine and its two major metabolites in human plasma

A rapid and sensitive HPLC method has been developed for the quantification of mirtazapine (MRZ), a noradrenergic and specific serotonergic inhibitor antidepressant (NaSSA) and its two major metabolites N-desmethylmirtazapine (NDM) and 8-hydroxymirtazapine (8-OHM) in human plasma. The separation was achieved using Chromolith C18 column and a mobile phase of acetonitrile: phosphate buffer (pH=3,...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2003