Problems Encountered in Fluctuating Flame Temperature Measurements by Thermocouple
نویسندگان
چکیده
Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either the voltage signal or indicated temperature for each test was recorded at sampling rates between 300-4,096 Hz. The trace was then plotted with respect to time or sample number so that time variation in voltage or temperature could be visualized and the average indicated temperature could be determined. For experiments where high sampling rates were used, the signal was analyzed using Fast Fourier Transforms (FFT) to determine the frequencies present in the thermocouple signal. This provided a basic observable as to whether or not the probe was able to follow flame oscillations. To enhance oscillations, for some experiments, the flame was forced. An analysis based on thermocouple time constant, coupled with the transfer function for a sinusoidal input was tested against the experimental results.
منابع مشابه
Beam-deflection optical tomography of a flame.
We report three-dimensional index-of-refraction measurements in a methane-air slot diffusion flame and a methane-air slot subsonic jet using beam-deflection optical tomography. The horizontal and vertical spatial resolutions are 0.26 and 0.635 mm, respectively. The peak temperature is calculated from the index-of-refraction map for the flame and compared with thermocouple temperature measurements.
متن کاملAn Approach to Thermocouple Measurements That Reduces Uncertainties in High-Temperature Environments
Obtaining accurate temperature measurements with thermocouples in flame environments is challenging due to the effects of radiative heat losses, as these losses are difficult to quantify. Efforts to minimize radiative losses by, for example, suction pyrometry often result in a significant sacrifice in spatial resolution. In this work, a new experimental methodology is presented that both minimi...
متن کاملOptical correction methods for a simultaneous LII and TC measurement of a low-sooting LPG diffusion flame
Simultaneous measurements with the TwoColor emission and Laser-Induced-Incandescence techniques on a diffusion laminar LPG bunsen flame were performed. The acquired images were filtered, perspective corrected and processed via an on purpose made procedure in order to reduce the measuring error. For quantitative measurements of the soot volume fraction and temperature a tungsten lamp calibration...
متن کاملTitle of Document : HOMOGENEOUS AND HETEROGENEOUS SENSORS FOR COMBUSTION SYSTEMS
Title of Document: HOMOGENEOUS AND HETEROGENEOUS SENSORS FOR COMBUSTION SYSTEMS Amir Eshaghi, PhD, 2012 Directed By: Distinguished University Professor, Professor Ashwani K. Gupta, Department of Mechanical Engineering Due to increasingly stringent emission regulations, it is important to develop clean combustors. Combustion behavior is very complex in almost all practical power plant systems. M...
متن کاملDiode laser atomic fluorescence temperature measurements in low-pressure flames
Temperature measurements have been performed in a low-pressure flame by the technique of diode laser induced atomic fluorescence. The experiments were done in a near-stoichiometric flat-flame of premixed methane, oxygen and nitrogen, at a pressure of 5.3 kPa. Indium atoms were seeded to the flame and probed using blue diode lasers; the lineshapes of the resulting fluorescence spectra were used ...
متن کامل