Role of SPECT-CT in radiotherapy.

نویسندگان

  • Sonya Sergieva
  • Iglika Mihailova
  • Zahary Zahariev
  • Milena Dimcheva
  • Stanislav Bozhikov
چکیده

PURPOSE The role of fusion imaging methods SPECT-CT and PET-CT is currently being investigated in radiotherapy (RT) treatment planning. SPECT and PET provide extra information for gross tumor volume (GTV) delineation. The purpose of this study was to evaluate the role of SPECT-CT in RT. METHODS SPECT-CT studies were performed in 55 patients with (99m)Tc-MIBI/Tetrofosmin (TF), with 99mTc-Nanoco, with 99mTc-MDP and with 185 MBq (131)I scan. All studies were performed with SPECT-CT camera, using low dose CT (130KeV, 30 mA, 3-5 mm step). Corresponding slices on SPECT-CT were compared to the diagnostic CT projections from the simulator. Diagnostic CT scans were performed using 3-5 mm slices both to aid volume definition and to create high quality digitally reconstructed radiographs (DRRs) to aid verification. The volumetric CT data were sent to the treatment planning system. RESULTS Application of SPECT-CT with (99m)Tc-MIBI/TF allowed to diagnose residual malignant mass or a recurrent tumor after combined (surgery and chemotherapy/ hormonotherapy/ therapy in studied patients with breast cancer, thymomas and lung cancer. SPECT-CT (99m)Tc-MIBI/ TF contributed to the definition of clinical target volume (CTV). SPECT-CT imaging of sentinel lymph nodes (SLNs) in medially located breast cancer was important for correct topography of intercostal space in cases with parasternal drainage. Irradiation of this subgroup of patients in conjunction with the chest wall and the supraclavicular region should be considered electively for each patient. The combined application of baseline whole body bone scintigraphy, followed by SPECT-CT fusion gave the possibility for correct radiotherapy planning of the GTV in tumor-induced bone disease. SPECT-CT is useful for diagnosis of recently discovered non-responsive to (131)I treatment patients with differentiated thyroid cancer. SPECT-CT data are important to avoid prescribed (131)I therapy and to define CTV for external beam RT (EBRT). CONCLUSION SPECT-CT images could be applicable in RT planning to precisely delinate tumor volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]

Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...

متن کامل

Evaluation of role of brain SPECT in diagnosis of post stroke dementia [Persian]

Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and ...

متن کامل

Complexity and accuracy of image registration methods in SPECT-guided radiation therapy.

The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung...

متن کامل

SPECT-CT fusion in the diagnosis of hyperparathyroidism

Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of B.U.ON. : official journal of the Balkan Union of Oncology

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2014