Search for Neutrinoless Double-Beta Decay of (130)Te with CUORE-0.
نویسندگان
چکیده
We report the results of a search for neutrinoless double-beta decay in a 9.8 kg yr exposure of (130)Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are 5.1±0.3 keV FWHM and 0.058±0.004(stat)±0.002(syst)counts/(keV kg yr), respectively. The median 90% C.L. lower-limit half-life sensitivity of the experiment is 2.9×10(24) yr and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of (130)Te and place a Bayesian lower bound on the decay half-life, T(1/2)(0ν)>2.7×10(24) yr at 90% C.L. Combining CUORE-0 data with the 19.75 kg yr exposure of (130)Te from the Cuoricino experiment we obtain T(1/2)(0ν)>4.0×10(24) yr at 90% C.L. (Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, m(ββ)<270-760 meV.
منابع مشابه
Status of Cuore experiment and last results from Cuoricino
CUORE is a cryogenic-bolometer detector consisting of 988 TeO 2 crystals, 750 g each, operated at a temperature of ∼8 mK, currently under construction in the underground Laboratori Nazionali del Gran Sasso. Its goal is to search for neutrinoless double beta decays with a sensitivity to the effective neutrino mass as low as a few tens of meV. CUORICINO, its pilot experiment, has proven the feasi...
متن کاملCryogenic Double Beta Decay Experiments: CUORE and CUORICINO
Cryogenic bolometers, with their excellent energy resolution, flexibility in material, and availability in high purity, are excellent detectors for the search for neutrinoless double beta decay. Kilogram-size single crystals of TeO2 are utilized in CUORICINO for an array with a total detector mass of 40.7 kg. CUORICINO currently sets the most stringent limit on the halflife of Te of T 1/2 ≥ 2.4...
متن کامل00 2 A Calorimetric Search on Double Beta Decay of 130
We report on the final results of a series of experiments on double decay of Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in Te and two others in Te . The remaining ones are made with natural t...
متن کاملPotential and Prospects for CUORE and CUORICINO experiments
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment projects to construct and operate an array of 1000 cryogenic thermal detectors of a mass of 760 g each to investigate rare events physics, in particular, double beta decay and non baryonic particle dark matter. A first step towards CUORE is CUORICINO, an array of 56 of such bolometers, currently being installed in the Gran...
متن کاملx / 02 11 07 1 v 3 2 5 Fe b 20 03 A Calorimetric Search on Double Beta Decay of 130
We report on the final results of a series of experiments on double beta decay of Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in Te and two others in Te . The remaining ones are made with natu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 115 10 شماره
صفحات -
تاریخ انتشار 2015