Wear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material

نویسندگان

  • Susann Grosse
  • Hans Kristian Haugland
  • Peer Lilleng
  • Peter Ellison
  • Geir Hallan
  • Paul Johan Høl
چکیده

Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/or aseptic loosening. Semiquantitative, histological tissue evaluations in 30 THR-patients revealed numerous wear debris-loaded macrophages, inflammatory cells, and necrosis in both groups. Particle load was highest in tissues adjacent to loosened cemented Ti stems that contained mainly submicron zirconium (Zr) dioxide particles. Particles containing pure Ti and Ti alloy elements were most abundant in tissues near retrieved uncemented cups. Polyethylene particles were also detected, but accounted only for a small portion of the total particle number. The blood concentrations of Ti and Zr were highly elevated in cases with high abrasive wear and osteolysis. Our findings indicate that wear particles of different chemical composition induced similar inflammatory responses, which suggests that particle size and load might be more important than the wear particle composition in periprosthetic inflammation and osteolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants

BACKGROUND There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants. METHODS This paper r...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.

After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By ...

متن کامل

Degree of the Polyethylene Component Wear – a Predictive Factor for the Outcome of Total Hip Arthroplasty

In patients suffering of osteoarthritis of the hip (a degenerative condition of the hip that finally leads to anatomical and functional impairment of the joint), the only efficient treatment in advanced stages of the disease is the surgical replacement of the joint with a total hip prosthesis. Unfortunately, despite improving the composition of the materials from which these prostheses are made...

متن کامل

Cemented versus uncemented femoral components in the ring hip prosthesis.

A prospective, randomised and independently assessed trial of the Ring UPM total hip replacement showed that the quality of the early result was better if the femoral prosthesis was cemented than if it was not. More patients with cemented prostheses were painfree at four months (58% cemented:42% uncemented) and at one year (63% cemented:50% uncemented), but at two years pain relief was equal in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 103  شماره 

صفحات  -

تاریخ انتشار 2015