Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording.

نویسندگان

  • Reid R Harrison
  • Ilya Kolb
  • Suhasa B Kodandaramaiah
  • Alexander A Chubykin
  • Aimei Yang
  • Mark F Bear
  • Edward S Boyden
  • Craig R Forest
چکیده

Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording

Reid R. Harrison, Ilya Kolb, Suhasa B. Kodandaramaiah, Alexander A. Chubykin, Aimei Yang, Mark F. Bear, Edward S. Boyden,* and Craig R. Forest* Intan Technologies, Los Angeles, California; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia; Media Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts; McGovern Institute, Mass...

متن کامل

P 18: Alterations of Electrophysiological Activity of Cerebellar Pukinje Cells of Rats Under Harmaline Toxicity

Introduction: Beta-carboline alkaloids of P. harmala are shown to have immune-modulatory effects in several studies. Extracts of this plant have significant anti-inflammatory effect via the inhibition of some inflammatory mediators including PGE2 and TNF-α. In postmortem studies, structural alterations to the cerebellum have been recognized, including Purkinje cell loss being re...

متن کامل

Robotic Automation of In Vivo Two-Photon Targeted Whole-Cell Patch-Clamp Electrophysiology

Whole-cell patch-clamp electrophysiological recording is a powerful technique for studying cellular function. While in vivo patch-clamp recording has recently benefited from automation, it is normally performed "blind," meaning that throughput for sampling some genetically or morphologically defined cell types is unacceptably low. One solution to this problem is to use two-photon microscopy to ...

متن کامل

Series resistance compensation for whole-cell patch-clamp studies using a membrane state estimator.

Whole-cell patch-clamp techniques are widely used to measure membrane currents from isolated cells. While suitable for a broad range of ionic currents, the series resistance (R(s)) of the recording pipette limits the bandwidth of the whole-cell configuration, making it difficult to measure rapid ionic currents. To increase bandwidth, it is necessary to compensate for R(s). Most methods of R(s) ...

متن کامل

P 17: Electrophysiological Effects of Cannabinoid Receptor Antagonist AM251 on Harmaline Toxicity in Rat’s Cerebellar Vermis Slices

Introduction: The Cannabinoid receptors (CBR) densities are high within the cerebellum. Cannabinoid receptors manipulations have been reported to cause altering the cerebellar functions. harmaline have immune-modulatory effects in several studies. i.e., significant anti-inflammatory effect via the inhibition of prostaglandin E2 (PGE2) and tumor necrosis factor alpha (TNF-α). Endocannabino...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 2015