First-in-man evaluation of the transapical APICA ASC™ access and closure device: the initial 10 patients.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to evaluate the initial and short-term results of a new apical access and closure device to facilitate and standardize the transapical (TA) approach to transcatheter aortic valve implantation (TAVI). METHODS The apical access, stabilization and closure (ASC™) device consists of three components: an introducer system, a left ventricular low-profile titanium coil and a closure cap. The ASC™ introducer system is anchored and rotated into the myocardium almost like a corkscrew, using the titanium coil. Following the TA-AVI procedure, the closure cap is introduced and delivered through the system into the titanium coil for final sealing. RESULTS A total of 11 high-risk elderly patients (EuroSCORE I: 27.8 ± 16.7; EuroSCORE II: 6.6 ± 5.0 and The Society of Thoracic Surgeons (STS) score: 5.9 ± 2.7%) were evaluated for TA-AVI by our interdisciplinary Heart Team and subsequently included in the trial after informed consent was obtained. One patient was excluded due to the presence of deep epicardial fat tissue. In all other cases, the titanium coil provided sufficient sealing throughout the procedure without the presence of perisheath bleeding. After delivery of the closure cap, no relevant bleeding was observed in any patient. Pericardial drainages were removed early in all patients. One patient suffered from non-device-related pericardial effusion requiring surgical decompression on postoperative day 6. Two patients suffered from delayed minor strokes, most likely due to arrhythmia. All patients received aspirin, clopidogrel and low molecular heparin after the procedure. Discharge echocardiography revealed no changes in left ventricular function when compared with baseline and no new onset wall motion abnormalities. All 10 patients were alive at 30 days. CONCLUSIONS TA access and closure are both feasible and safe using the APICA ASC™ device. The system facilitates and standardizes TA access and closure by providing a sufficient and secure sealing during and after the TA-AVI procedure.
منابع مشابه
Outcomes and Complications of Primary Closure of Wounds in the War Wounded Referred to a Hospital in Tehran in 2017
Background and Aim: In most studies, in the treatment of war wounds, debridement and delayed wound healing have been suggested and there has been no emphasis on initial wound closure. The aim of this study was to determine the outcomes and complications of primary closure of wounds in war-wounded referred to a hospital in Tehran, Iran. Methods: In this cross-sectional study, 102 war-wounded wit...
متن کاملApical access and closure devices for transapical transcatheter heart valve procedures.
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages ...
متن کاملAccess site complications after peripheral vascular interventions: incidence, predictors, and outcomes.
BACKGROUND Access site hematomas and pseudoaneurysms are the most frequent complications of peripheral vascular intervention (PVI); however, their incidence and risk factors remain unclear. METHODS AND RESULTS We retrospectively analyzed data from the multicenter Vascular Quality Initiative on 22 226 patients who underwent 27 048 PVI from August 2007 to May 2013. Primary end points included i...
متن کاملThyroid Ultrasonography in Differentiation between Graves’ Disease and Hashimoto’s Thyroiditis
Objective: Graves’ disease and Hashimoto’s thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiat...
متن کاملTransapical transcatheter device closure of relapse left ventricular diverticulum: a novel minimally invasive technique for reoperation
We describe a novel minimally invasive technique, transapical transcatheter device closure of relapse left ventricular diverticulum (LVD) under transesophageal echocardiography (TEE) guidance. The patient previously underwent LVD primary repair and mitral valvular replacement. The anatomical characteristics of the relapse LVD and its adjacent structures are detailedly delineated by echocardiogr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 44 6 شماره
صفحات -
تاریخ انتشار 2013