Area x-ray detector based on a lens-coupled charge-coupled device
نویسندگان
چکیده
An area x-ray detector constructed using commercially available “off-the-shelf” parts is described and its performance is characterized. The detector consists of a 1024 1024 pixel charge-coupled device CCD camera optically coupled to x-ray sensitive phosphor screen using a standard 35 mm camera lens. The conversion efficiency, spatial nonuniformity, spatial resolution and the detective quantum efficiency of the detector have been measured. Also shown is an example of data taken with the detector. The detector is a relatively low-cost device suitable for a wide variety of quantitative x-ray experiments where the input area need not be larger than about 70 mm across. © 2005 American Institute of Physics. DOI: 10.1063/1.2001307
منابع مشابه
Charge-coupled device area x-ray detectors
Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...
متن کاملCalibration procedures for charge-coupled device x-ray detectors
Calibration procedures are described for use with electronic x-ray detectors, with an emphasis on detectors based on fiber-optically coupled charge-coupled devices. Methods are detailed for removing spurious events, pixel pedestals, dark-current, spatial distortion, and intensity response variations for both small-angle and wide-angle applications. The accuracy of the calibration procedures is ...
متن کاملSuperconducting Microstrip-Fed Antenna Coupled to a Microwave Kinetic Inductance Detector
A proper antenna to couple to a microstrip Microwave Kinetic Inductance Detector (MKID) is designed and simulated. A twin-slot microstrip-fed inline antenna is designed for frequency band of 600-720~GHz integrated with an elliptical lens and coupled to the MKID. A systematic design procedure for design of such antenna with microstrip inline feeding is presented. Whole structure of lens and twin...
متن کاملProton irradiation of a swept charge device at cryogenic temperature and the subsequent annealing
A number of studies have demonstrated that a room temperature proton irradiation may not be sufficient to provide an accurate estimation of the impact of the space radiation environment on detector performance. This is a result of the relationship between defect mobility and temperature, causing the performance to vary subject to the temperature history of the device from the point at which it ...
متن کاملImplementation of a Data Acquisition System for 2×2 Fiber Optic Taper Array Coupled Digital X-ray Detector
Fiber optic taper (FOP) array coupled digital x-ray detector can be an ideal choice for large area high resolution x-ray imaging, but its data acquisition system is a challenge, for the reasons such as restrictions of hardware design due to the shape of the FOP array, long distance control requirement in x-ray environment, and arrangement of data transmission sequence among multiple CCD/CMOS im...
متن کامل