Signal separation and parameter estimation in noninvasive dual-tracer PET scans using reference-region approaches.

نویسندگان

  • Aniket D Joshi
  • Robert A Koeppe
  • Jeffrey A Fessler
  • Michael R Kilbourn
چکیده

This is the first study to report results from a noninvasive dual-tracer positron emission tomography (PET) in humans not requiring arterial sampling, in which two radiotracers were injected closely in time within the same scan. These studies yield near simultaneous information on two different neuropharmacological systems, providing better characterization of a subject's neurologic condition. The noninvasive dual-tracer approach described in this study is based on the primary assumption that an appropriate bolus plus constant infusion protocol brings the reference tissue of the first radiotracer to steady state before injection of the second tracer. Two methods for separation of time-activity curves (TACs) and parameter estimation were investigated, namely (1) an extrapolation method, in which TACs of the first tracer were extrapolated over total scan duration followed by subtraction from dual-tracer TACs and (2) a simultaneous fitting method, in which reference-region models for both tracers were fitted simultaneously to dual-tracer TACs. Combinations of two reversible tracers ([(11)C]flumazenil and [(11)C]dihydrotetrabenazine) or one reversible and one irreversible tracer ([(11)C]N-methylpiperidinyl propionate) were used. After the dual-tracer scan, a single-tracer (ST) scan using one of the tracers was obtained for comparison of the dual-tracer results. Both approaches provided parameter estimates with intersubject regions-of-interest means typically within 10% of those obtained from ST scans without an appreciable increase in variance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-scan dual-tracer FLT+FDG PET tumor characterization.

Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapid...

متن کامل

Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

UNLABELLED Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. METHODS Consecutive adult patients with hepatocellula...

متن کامل

Improving the velocity tracking of cruise control system by using adaptive methods

Accurate and correct performance of controller in cruise control systems is important. Hence, in such systems, controller should optimize itself against noise and probable changes in system dynamic. As a matter of fact, in this article three approaches have been conducted to-ward this purpose: MIT, direct estimation and indirect estimation. These approaches are used as controllers to track refe...

متن کامل

Estimating neurotransmitter kinetics with ntPET: A simulation study of temporal precision and effects of biased data

We recently introduced neurotransmitter PET (ntPET), an analysis technique that estimates the kinetics of stimulus-induced neurotransmitter (NT) release. Here, we evaluate two formulations of ntPET. The arterial (ART) approach measures the tracer input function (TIF) directly. The reference (REF) approach derives the TIF from reference region data. Arterial sampling is considered the gold stand...

متن کامل

Estimation of Potential Evapotranspiration and Crop Coefficient of Wheat at Rupandehi District of Nepal

This study is carried out to estimate the potential evapotranspiration (PET) and crop coefficient (Kc) for Wheat, BL 3235 variety. A lysimeter is installed to estimate PET at the experimental farm of Agricultural Research Center of Bhairahawa, which is located in western part of Nepal. The Blaney-Criddle formula is used to estimate the Kc for wheat. The estimated values of PET and Kc for wheat ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 2009