Patch recordings from the electrocytes of electrophorus. Na channel gating currents
نویسندگان
چکیده
Gating currents were recorded at 11 degrees C in cell-attached and inside-out patches from the innervated membrane of Electrophorus main organ electrocytes. With pipette tip diameters of 3-8 microns, maximal charge measured in patches ranged from 0.74 to 7.19 fC. The general features of the gating currents are similar to those from the squid giant axon. The steady-state voltage dependence of the ON gating charge was characterized by an effective valence of 1.3 +/- 0.4 and a midpoint voltage of -56 +/- 7 mV. The charge vs. voltage relation lies approximately 30 mV negative to the channel open probability curve. The ratio of the time constants of the OFF gating current and the Na current was 2.3 at -120 mV and equal at -80 mV. Charge immobilization and Na current inactivation develop with comparable time courses and have very similar voltage dependences. Between 60 and 80% of the charge is temporarily immobilized by inactivation.
منابع مشابه
Patch recordings from the electrocytes of Electrophorus electricus. Na currents and PNa/PK variability
Sodium currents were recorded in cell-attached and inside-out patches from the innervated membrane of Electrophorus electrocytes. Electrocytes from Sachs and main electric organs were prepared as described by Pasquale et al. (1986. J. Membr. Biol. 93:195.). Maximal currents in the Sachs organ, measured with 1-2 microns diameter patch pipettes and at room temperature, were in the range of 20 to ...
متن کاملPatch Recordings from the Electrocytes
Sodium currents were recorded in cell-attached and inside-out patches from the innervated membrane of Electrophorus electrocytes. Electrocytes from Sachs and main electric organs were prepared as described by Pasquale et al. (1986.J. Membr. Biol. 93:195.). Maximal currents in the Sachs organ, measured with 1-2-p.m diameter patch pipettes and at room temperature, were in the range of 20 to 300 p...
متن کاملEffects of heart failure on brain-type Na+ channels in rabbit ventricular myocytes.
AIMS Brain-type alpha-subunit isoforms of the Na(+) channel are present in various cardiac tissue types and may control pacemaker activity and excitation-contraction coupling. Heart failure (HF) alters pacemaker activity and excitation-contraction coupling. Here, we studied whether HF alters brain-type Na(+) channel properties. METHODS AND RESULTS HF was induced in rabbits by volume/pressure ...
متن کاملModal gating of Na+ channels as a mechanism of persistent Na+ current in pyramidal neurons from rat and cat sensorimotor cortex.
The kinetic behavior of brain Na+ channels was studied in pyramidal cells from rat and cat sensorimotor cortex using either the thin slice preparation or acutely isolated neurons. Single-channel recordings were obtained in the cell-attached and inside-out configuration of the patch-clamp technique. Na+ channels had a conductance of about 16 pS. Patches always contained several Na+ channels, usu...
متن کاملNoradrenergic System Increases Miniature Excitatory Synaptic Currents in the Barrel Cortex
Introduction: Neurons in layer II and III of the somatosensory cortex in rats show high frequency (33 ± 13 Hz) of miniature excitatory postsynaptic currents (mEPSCs) that their rates and amplitudes are independent of sodium channels. There are some changes in these currents in neurodegenerative and psychological disorders. Regarding to well known roles of the neuromodulatory brain systems in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of General Physiology
دوره 98 شماره
صفحات -