Beta Decay Spectrum using a CdZnTe Array

نویسنده

  • J. V. Dawson
چکیده

We present 11 independent measurements of the half-life and spectral shape of the 4-fold forbidden beta decay of Cd using CdZnTe semiconductors with a total combined lifetime of 6.58 kg days. Our overall result gives a half-life of (8.00 ± 0.11(stat) ± 0.24(sys)) × 10 years and a Q value of 322.2 ± 0.3(stat) ± 0.9(sys) keV. For the first time half-lives well beyond 10 years have been deduced with a statistically representative sample of independent measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of multi-element CdZnTe detectors

Single-element CdZnTe detectors are limited in size, and therefore efficiency, by the poor hole transport, even with a coplanar grid. We are investigating the possibility of a 27-element (3 × 3 × 3) array using 15 mm × 15 mm × 15 mm elements for gamma-ray energies to 10 MeV for NASA planetary missions. We present experimental results for combinations of various size coplanar grid detectors usin...

متن کامل

0 30 10 07 v 1 1 4 Ja n 20 03 A Search for various Double Beta Decay Modes of Cd , Te and Zn Isotopes

Various double beta decay modes of Cd, Zn and Te isotopes are explored with the help of CdTe and CdZnTe semiconductor detectors. The data set is splitted in an energy range below 1MeV having a statistics of 134.5 g·d and one above 1MeV resulting in 532 g·d. No signals were observed in all channels under investigation. New improved limits for the neutrinoless double beta decay of Zn of T1/2 > 1....

متن کامل

0 30 10 07 v 2 8 A pr 2 00 3 A Search for various Double Beta Decay Modes of Cd , Te and Zn Isotopes

Various double beta decay modes of Cd, Zn and Te isotopes are explored with the help of CdTe and CdZnTe semiconductor detectors. The data set is splitted in an energy range below 1MeV having a statistics of 134.5 g·d and one above 1MeV resulting in 532 g·d. No signals were observed in all channels under investigation. New improved limits for the neutrinoless double beta decay of Zn of T1/2 > 1....

متن کامل

Gamma Spectroscopy with Germanium Detectors

The MAJORANA collaboration[1] aims to detect neutrino-less double beta decay (0νββ) in Ge, using an array of germanium p-type point contact detectors. An important factor in this effort is the minimization of backgrounds from any hardware which is needed to operate the detectors. In order to best understand and minimize this background, one must analyze the gamma spectrum from these pieces of h...

متن کامل

Improvement of Energy Characteristics of Semiconductor Detectors Using Genetic Algorithms

A new charge loss correction method using genetic algorithms (GA) has been proposed to improve gamma ray energy spectrum characteristics of CdZnTe detectors. The correction method is based on the analysis of signal waveform shapes. GA recognizes the charge generation places for each signal and provides the related corrective factors of the pulse heights; the corrected energy spectrum was obtain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009