A feasibility study of a prototype PET insert device to convert a general-purpose animal PET scanner to higher resolution.

نویسندگان

  • Heyu Wu
  • Debashish Pal
  • Joseph A O'Sullivan
  • Yuan-Chuan Tai
چکیده

UNLABELLED We developed a prototype system to evaluate the feasibility of using a PET insert device to achieve higher resolution from a general-purpose animal PET scanner. METHODS The system consists of a high-resolution PET detector, a computer-controlled rotation stage, and a custom mounting plate. The detector consists of a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.8 x 1.66 x 3.75 mm(3) each) directly coupled to a position-sensitive photomultiplier tube (PS-PMT). The detector signals were fed into the scanner electronics to establish coincidences between the 2 systems. The detector was mounted to a rotation stage that is attached to the scanner via the custom mounting plate after removing the transmission source holder. The rotation stage was concentric with the center of the scanner. The angular offset of the insert detector was calibrated via optimizing point-source images. In all imaging experiments, coincidence data were collected from 9 angles to provide 180 degrees sampling. A (22)Na point source was imaged at different offsets from the center to characterize the in-plane resolution of the insert system. A (68)Ge point source was stepped across the axial field of view to measure the sensitivity of the system. A 23.2-g mouse was injected with 38.5 MBq of (18)F-fluoride and imaged at 3 h after injection for 2 h. RESULTS The transverse image resolution of the PET insert device ranges from 1.1- to 1.4-mm full width at half maximum (FWHM) without correction for the point-source dimension. This corresponds to approximately 33% improvement over the resolution of the original scanner (1.7- to 1.8-mm FWHM) in 2 of the 3 directions. The sensitivity of the device is 0.064% at the center of the field, 46-fold lower than the sensitivity of an existing animal PET scanner. The mouse bone scan had improved image resolution using the PET insert device over that of the existing animal PET scanner alone. CONCLUSION We have demonstrated the feasibility of using a high-resolution insert device in an existing PET scanner to provide high-resolution PET. A PET insert device with more detector modules will improve sensitivity and may become an alternative to special-purpose PET systems for high-resolution PET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.

UNLABELLED A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. METHODS The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an o...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling

Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...

متن کامل

Validation and evaluation of a GATE model for MAMMI PET scanner

Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard.  Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...

متن کامل

THESIS DEFENSE DEBASHISH PAL Biomedical Engineering Department Washington University in St. Louis IMAGE RECONSTRUCTION FOR A HIGH RESOLUTION PET-INSERT SCANNER

Positron emission tomography (PET) is widely used in clinical diagnosis as it provides metabolic and functional information about an organ of interest or the whole body. We are developing novel insert devices for existing PET scanners to achieve higher resolution in selected regions of interest such as the head, neck, breast, or abdomen. In this work, the insert is a ring of high-resolution det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2008